19. External Supply Pumps Turning on in Mid Cycle Without Being
Programmed to Do So
External supply pumps are turning on mid
cycle without being programmed to do so.
This may be the result of resistors (12K 5W)
on the output board allowing low voltage
leaks (between 100 and 120 VAC).
Replace the resistors on the
output board (that correspond
to the pumps that are turning
on in mid cycle) as needed.