Technical specifications

Installation instructions

Maintenance

for corresponding “CWF” and “IWF” 

models, see page 5 for complete model 

list.

Part No. D0875R7 

Code: 249/00353/10 

January 2011

Summary of Contents for WFF100

Page 1: ...WFF165 Instruction manual Washer Extractors Technical specifications Installation instructions Maintenance for corresponding CWF and IWF models see page 5 for complete model list Part No D0875R7 Code...

Page 2: ......

Page 3: ...24 Surface 24 Anchoring on a metal base 24 Directly on the ground 24 Mounting Bolt Hole Locations for machines WFF65 IWF065 IWF014 CWF065 CWF014 25 Mounting Bolt Hole Locations for machines WFF75 IWF...

Page 4: ...44 Internal connections of the electrical heating 44 Maintenance instruction of the machine 45 End of day 45 General maintenance 45 Periodical maintenance 45 Annual maintenance 46 Contact Information...

Page 5: ...F014SDM IWF014SEM IWF014SRM IWF014SLM IWF014SXM IWF014SYM IWF018ANM IWF018MNM IWF018MCM IWF018MDM IWF018MEM IWF018MLM IWF018MXM IWF018MYM IWF018SCM IWF018SDM IWF018SEM IWF018SRM IWF018SLM IWF018SXM IW...

Page 6: ...M IWF100MNM IWF100MCM IWF100MDM IWF100MEM IWF100MLM IWF100MXM IWF100MYM IWF100SCM IWF100SDM IWF100SEM IWF100SRM IWF100SLM IWF100SXM IWF100SYM IWF100ZNM IWF100ZCM IWF100ZDM IWF100ZEM IWF100ZLM IWF100ZX...

Page 7: ...M CWF030MCM CWF030MDM CWF030MEM CWF030MLM CWF030MXM CWF030MYM CWF065ANM CWF065MNM CWF065MCM CWF065MDM CWF065MEM CWF065MLM CWF065MXM CWF065MYM CWF074ANM CWF074MNM CWF074MCM CWF074MDM CWF074MEM CWF074ML...

Page 8: ...ds MOVING PARTS HAZARD This symbol alerts you to the presence of possible dangerous moving parts within the machine Guards should always be in place when the machine is in operation Be very careful wh...

Page 9: ...ded over to the applicable collection point for the recycling of electrical and electronic equipment Ensuring this product is disposed of correctly you will help prevent potential negative consequence...

Page 10: ...fety Decals Safety decals appear at crucial locations on the machine Failure to maintain legible safety decals could result in injury to the operator or service technician To provide personal safety a...

Page 11: ...at if not avoided will cause severe personal injury or death 9 Do not install or store the washer where it will be exposed to water and or weather 10 Do not tamper with the controls 11 Do not repair o...

Page 12: ...y safety devices 27 Failure to install maintain and or operate this washer according to the manufacturer s instructions may result in conditions which can produce bodily injury and or property damage...

Page 13: ...and attempt to start the machine The machine should not start with the door unlocked c Close and lock the door and start a cycle Attempt to open the door while the cycle is in progress The door should...

Page 14: ...Speed Wash 10 50 tr min RPM Distribution 85 tr min RPM Spin 700 tr min RPM G factor Spin 145 Motor 3 phase 4p 1470 tr min 0 55kW 0 73HP Drain valve 2 Water supply Hard soft warm water 3 4 Steam connec...

Page 15: ...5 2 17 55 2 17 220 8 66 48 1 89 273 10 75 37 1 46 5 0 2 287 11 3 670 26 37 728 28 66 69 2 72 15 3 Dimensions WFF65 IWF065 IWF014 CWF065 CWF014 A Ventilation soap dispenser B Liquid soap connetions C H...

Page 16: ...08 mm 20 inch Speed Wash 10 50 tr min RPM Distribution 85 tr min RPM Spin 700 tr min RPM G factor Spin 145 Motor 3 phase 4p 1470 tr min 0 55kW 0 73HP Drain valve 2 Water supply Hard soft warm water 3...

Page 17: ...5 2 17 55 2 17 69 2 72 728 28 66 670 26 37 327 12 87 5 0 2 37 1 46 233 9 17 48 1 89 220 8 66 17 3 Dimensions WFF75 IWF074 IWF018 CWF074 CWF018 A Ventilation soap dispenser B Liquid soap connetions C H...

Page 18: ...08 mm 20 inch Speed Wash 10 50 tr min RPM Distribution 85 tr min RPM Spin 700 tr min RPM G factor Spin 145 Motor 3 phase 4p 1470 tr min 0 55kW 0 73HP Drain valve 2 Water supply Hard soft warm water 3...

Page 19: ...55 2 17 55 2 17 69 2 72 828 32 6 770 30 31 427 16 81 5 0 2 37 1 46 233 9 17 48 1 89 220 8 66 19 Dimensions WFF100 IWF100 IWF025 CWF100 CWF025 A Ventilation soap dispenser B Liquid soap connetions C H...

Page 20: ...6 mm 23 85 inch Speed Wash 10 50 tr min RPM Distribution 85 tr min RPM Spin 632 tr min RPM G factor Spin 145 Motor 3 phase 4p 1470 tr min 1 10kW 1 47HP Drain valve 2 Water supply Hard soft warm water...

Page 21: ...76 70 2 76 220 8 66 33 1 3 84 3 31 260 10 24 28 1 1 410 16 14 82 3 23 816 32 12 760 29 92 21 3 Dimensions WFF135 IWF135 IWF030 CWF135 CWF030 A Ventilation soap dispenser B Liquid soap connetions C Ha...

Page 22: ...ter 606 mm 23 85 inch Speed Wash 10 50 tr min RPM Distribution 85 tr min RPM Spin 632 tr min RPM G factor Spin 145 Motor 3 phase 4p 1470 tr min 1 10kW 1 47HP Drain valve 2 Water supply Hard soft warm...

Page 23: ...84 3 31 L K 109 4 29 F E D G I C 780 30 71 1204 47 4 1175 46 26 455 17 91 640 25 2 70 2 76 70 2 76 23 3 Dimensions WFF165 IWF165 CWF165 A Ventilation soap dispenser B Liquid soap connetions C Hard wa...

Page 24: ...00 25 cm 9 48 inch WFF135 165 35 cm 13 77 inch C Washer 40x17x4 1 57x0 60x0 15 D Nut M12 1 2 WFF65 75 100 M16 5 8 WFF135 165 E Base of the machine IMPORTANT Machine bolts should be re checked on a qua...

Page 25: ...0 22 05 550 21 65 660 25 98 55 2 17 55 2 17 273 10 75 287 11 3 48 1 89 37 1 46 645 25 4 2 2 0 8 7 25 4 Mounting Bolt Hole Locations for machines WFF65 IWF065 IWF014 CWF065 CWF014 Legend metric mm inch...

Page 26: ...22 05 550 21 65 660 25 98 55 2 17 55 2 17 48 1 89 37 1 46 645 1 25 4 327 12 87 233 9 17 2 2 0 8 7 26 4 Mounting Bolt Hole Locations for machines WFF75 IWF074 IWF018 CWF074 CWF018 Legend metric mm inc...

Page 27: ...25 99 550 21 65 660 25 98 55 2 17 55 2 17 48 1 89 37 1 46 745 29 33 427 16 81 233 9 17 2 2 0 8 7 27 Mounting Bolt Hole Locations for machines WFF100 IWF100 IWF025 CWF100 CWF025 4 Legend metric mm inc...

Page 28: ...0 30 71 640 25 2 70 2 76 731 28 78 410 16 14 70 2 76 33 1 3 28 1 1 260 10 24 2 2 0 8 7 670 26 38 28 Mounting Bolt Hole Locations for machines WFF135 IWF135 IWF030 CWF135 CWF030 4 Legend metric mm inch...

Page 29: ...770 30 31 2 2 0 8 7 260 10 24 28 1 1 33 1 3 70 2 76 510 20 08 831 32 72 70 2 76 640 25 2 780 30 71 29 Mounting Bolt Hole Locations for machines WFF165 IWF165 CWF165 4 Legend metric mm inches...

Page 30: ...F75 IWF074 IWF018 CWF074 CWF018 65 l 2 29 ft For the WFF100 WFF100 IWF100 IWF025 CWF100 CWF025 80 l 2 82 ft For the WFF135 WFF135 IWF135 IWF030 CWF135 CWF030 100 l 3 53 ft For the WFF165 WFF165 IWF165...

Page 31: ...AC drive provides overload protection for the drive motor However a separate single or three phase circuit breaker must be installed for complete electrical overload protection This prevents damage t...

Page 32: ...nd proper operation the washer extractor must be grounded in accordance with state and local standards If such standards are not available grounding must conform to the National Electric Code article...

Page 33: ...ain switch cover plate at back of machine see chapter dimensions part F Run power cable through the cabinet knock out located directly below the cover plate Before installing obtain and install a cord...

Page 34: ...ntified as the neutral wire to the bottom terminal of the auxiliary contactor on the power contactor switch marked N 200 240 volts 1 Phase 2 wire PE 60 Hertz called 1 phase 60 Hz X voltage With supply...

Page 35: ...NON US US NON US N 440 480 50 60 3 3 PE 3 10 10 14 2 5 3x2 kW 12 15 16 14 2 5 P 380 415 50 60 3 3 N PE 7 15 16 14 2 5 16 20 20 12 4 0 Q 200 240 50 60 3 3 PE 7 15 16 14 2 5 23 30 32 10 6 0 X 200 240 5...

Page 36: ...415 50 60 3 3 N PE 7 15 16 14 2 5 16 20 20 12 4 0 Q 200 240 50 60 3 3 PE 7 15 16 14 2 5 23 30 32 10 6 0 X 200 240 50 60 1 3 2 3 PE 7 15 16 14 2 5 N A N A N A N A Alternative Electric Heat Options N 4...

Page 37: ...0 415 50 60 3 3 N PE 7 15 16 14 2 5 21 30 32 10 6 0 Q 200 240 50 60 3 3 PE 7 15 16 14 2 5 30 40 40 8 10 0 X 200 240 50 60 1 3 2 3 PE 7 15 16 14 2 5 N A N A N A N A Alternative Electric Heat Options N...

Page 38: ...N US US NON US N 440 480 50 60 3 3 PE 4 10 10 14 2 5 6x2 kW 21 30 30 10 6 0 P 380 415 50 60 3 3 N PE 12 15 16 14 2 5 30 40 40 8 10 0 Q 200 240 50 60 3 3 PE 12 15 16 14 2 5 42 50 50 8 10 0 X 200 240 50...

Page 39: ...0 4 25 0 X 200 240 50 60 1 3 2 3 PE 12 15 16 14 2 5 N A N A N A N A Alternative Electric Heat Options N 440 480 50 60 3 3 PE 3x3 kW 3x2 kW 26 30 30 10 6 0 P 380 415 50 60 3 3 N PE 34 40 40 8 10 0 Q 20...

Page 40: ...Check at regular intervals for chemical leaks CAUTION Drill out plugs and nipples before making supply hose connection Failure to do so can cause buildup of pressure and risk a tubing rupture Electric...

Page 41: ...e transformed to other values to drive other type soap pumps Example pumps 24V See Label 7 Also pumps with different operating tension can be combined Example 5 pumps 220V and 1 pump 24V See Label 8 W...

Page 42: ...be connected The right connectors form a potential free output contact as a result of which the operating panel detects when the machine is activated or not The left connectors receive the signal by...

Page 43: ...inlets Recommended pressure bar Recommended pressure psi Maximum pressure bar Maximum pressure psi For the WFF65 WFF65 IWF065 IWF014 CWF065 CWF014 3 8 1 2 0 5 5 30 80 5 5 80 For the WFF75 WFF75 IWF074...

Page 44: ...LC1D0901 12kw 3x2kw 3x2kw See label 14 See label 14 LC1D1810 LC1D1810 See label 15 LC1D0901 15kw 3x2kw 3x2kw See label 14 See label 14 LC1D1810 LC1D1810 See label 15 LC1D1810 18kw 3x3kw 3x3kw See lab...

Page 45: ...hange the setting of the water inlet taps on boiler fed machines once these have been installed It is recommended to leave the door and soap dispenser open after use to ventilate the machine Check for...

Page 46: ...figure Annual maintenance Belt tension Belt tension testing table Model Belt Frequency Hz Tension force N Deflection mm Deflection force MIN MAX MIN MAX at MIN tension at MAX tension MAX WFF65 PJ8 13...

Page 47: ...Information Nameplate Nameplate Location The nameplate is located at the rear of the machine Always provide the machine s serial number and model number when ordering parts or when seeking technical a...

Page 48: ...acement Parts If literature or replacement parts are required contact the source from which the machine was purchased or contact the phone numbers or websites shown on the nameplate Position of the Se...