37
WARNING
The washer-extractor should be connected to an individual branch
circuit not shared with lighting or other equipment.
4
Electrical Specifications WFF100, IWF100, IWF025, CWF100, CWF025
100 liters / 25 pounds
Boiler Fed/Steam Heat
Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full
Load Amps
Recommended Circuit
Breaker (US-market)
AWG/mm2
kW Standard
Heating Elements
Full
Load Amps
Recommended
Circuit Breaker (US-
market)
AWG/mm2
US NON-US
US NON-US
N
440-480 50/60
3
3+PE
3
10
10
14/2.5
3x3 kW
17
20
20
12/4.0
P
380-415 50/60
3
3+N+PE
7
15
16
14/2.5
21
30
32
10/6.0
Q
200-240 50/60
3
3+PE
7
15
16
14/2.5
30
40
40
8/10.0
X
200-240 50/60
1/3
2/3+PE
7
15
16
14/2.5
N/A N/A
N/A
N/A
Alternative Electric Heat Options
N
440-480 50/60
3
3+PE
3x1.4 kW
N/A N/A
N/A
N/A
P
380-415 50/60
3
3+N+PE
13
15
16
14/2.5
Q
200-240 50/60
3
3+PE
18
20
20
12/4.0
X
200-240 50/60
1/3
2/3+PE
N/A N/A
N/A
N/A
N
440-480 50/60
3
3+PE
3x2 kW
N/A N/A
N/A
N/A
P
380-415 50/60
3
3+N+PE
16
20
20
12/4.0
Q
200-240 50/60
3
3+PE
23
30
32
10/6.0
X
200-240 50/60
1/3
2/3+PE
N/A N/A
N/A
N/A
N
440-480 50/60
3
3+PE
3x4 kW
20
30
25
10/6.0
P
380-415 50/60
3
3+N+PE
24
30
30
10/6.0
Q
200-240 50/60
3
3+PE
N/A N/A
N/A
N/A
X
200-240 50/60
1/3
2/3+PE
N/A N/A
N/A
N/A
Table 4