196
70380601
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
LED OPL and UniLinc Troubleshooting
80. Troubleshooting From Control to Slip Ring Assembly
1. At the control, unplug harness at header H5 (Refer to
Figure 20
).
2. At the slip ring assembly, unplug the moisture sensing harness on the control side of the slip ring assembly
(Refer to
Figure 22
).
3. The harness from the control leads into a junction panel before reaching the slip ring assembly. Inspect
junction panel for intermittent connections or unplugged harnesses (Refer to
Figure 23
).
TMB2398S
1
Connector
2
Black Wire
3
Moisture Sensing Harness
4
Slip Ring Assembly Harness
5
Set-Screw
6
White Wire
7
Screws
Figure 22
7
4
6
3
5
2
1