Machine Troubleshooting
7. Burner Does Not Ignite
Burner Does
Not Ignite
Is there
an improper or
inadequate exhaust
system?
No
Are there
blown fuses or
tripped circuit breakers
in external electric
supply line?
Is
drying
selector in the
“Cool Down”
portion of
cycle?
No
Refer to
Installation
Manual
for
exhaust system
requirements.
Yes
Check fuses or
circuit breaker.
Yes
Reset switch on
microprocessor.
Yes
Is
the cabinet
thermostat
inoperative?
Yes
Test thermostat
and replace if
inoperative.
Is
there an
insufficient gas
supply?
Yes
Open partially closed
gas shut-off valve, or
correct low gas
pressure. Check
manifold pressure
and adjust to
pressure specified on
serial plate. If
pressure cannot be
obtained, have your
local gas company
check main gas
pressure.
No
Is there
inadequate
ductwork and
make-up
air?
No
Tumble Dryer is
equipped for type of
gas specified on
serial plate. If
orifices are
different from that
specified on serial
plate, obtain and
install correct orifices.
Yes
Clean lint
compartment. Check
damper for lint
accumulation. Check
ductwork for lint
buildup.
Yes
Refer to
Installation
Manual
to ensure
that ductwork and
make-up air
openings are sized
accurately.
Yes
Is there
lint
buildup?
Are the
orifices
incorrect?
TMB2187S-a
No
Continued on
next page
Is
stove limit
thermostat 1
inoperative?
Test thermostat 1
and replace if
inoperative.
No
Yes
Is
stove limit
thermostat 2
inoperative?
Test thermostat 2
and replace if
inoperative.
No
No
No
No
Yes