Summary of Contents for DALPH1022

Page 1: ...Alliance Products LLC Murfreesboro TN 37129 1 800 522 3973 OPERATIONS MANUAL DALPH1022 HEATED PELLET PLATE DISPENSER Rev 4 14 ...

Page 2: ...L INFORMATION 3 RECEIVING INSPECTIONS 3 INSTALLATION 4 ELECTRICAL 5 START UP 6 CLEANING 7 TROUBLESHOOTING 8 PARTS LIST DIAGRAMS 9 PREVENTIVE MAINTENANCE 13 WARRANTY 14 SERVICE AND ASSISTANCE 14 RETURN POLICY 15 ...

Page 3: ...50 Total Capacity 86 100 Overall Dimensions Length 36 Width 23 3 4 Height 42 13 16 Electrical Requirements Voltage Phase 208V 1 Amperage 17 2 Cycle 60 NEMA Plug Configuration 6 20P Shipping Weight approx 285 lbs RECEIVING INSPECTIONS NOTE All Alliance units are factory tested for performance prior to shipment Upon receipt the crate should be inspected for visual damage any damage should be reporte...

Page 4: ...e can not be externally detected 1 Save all packing material 2 Contact an Alliance customer service representative and alert them to the situation 3 The receiver must call the carrier to schedule an inspection of the damaged merchandise INSTALLATION NOTE The installation instructions are similar for all models of pellet plate heaters A Remove all packaging materials from the unit Remove the protec...

Page 5: ...the unit near enough to the electrical outlet so the power cord is not stretched or strained Once the unit is properly located push down on the two caster brakes to lock them into place All pellet plate heaters are provided with a NEMA plug type 6 20P WARNING Every pellet plate heater is fitted with a grounded power cord and must be connected to a properly grounded receptacle Each receptacle must ...

Page 6: ...s a quick and even heat absorption by the contents Once the air inside the cabinet has reached the desired and preset temperature the thermostats will continue to maintain this temperature by regulating the power to the heating elements The fan motor will run as long as each well is energized B Loading Load carrier shelf by carefully stacking the pellets plates in each cavity Always keep the load ...

Page 7: ... elevator mechanisms up and out place them on a work surface You can wipe down the mechanisms with a damp cloth to clean them 3 Clean out any debris inside the cabinet and wipe the cabinet down with a damp cloth 4 Place the elevator mechanisms back inside the cabinet and clean the outside of the cabinet with a mild non abrasive soap or detergent in a warm water solution A commercial stainless stee...

Page 8: ...ch 2 Replace power switch 3 Loose wiring 3 Check and secure wiring D Pellet plate temperature 1 Thermostat set too low 1 Readjust thermostat Is too low fan operating 2 Jammed or loose fan blade 2 Replace or tighten blade 3 Cover is open 3 Close cover E Pellet plate temperature 1 Thermostat is set too high 1 Readjust thermostat Is too high fan operating 2 Closed thermostat 2 Replace thermostat 3 Cl...

Page 9: ...P00101 1 9 On Off Switch 030P00109 2 10 Motor 208 230V 60hz 1ph 3200 rpm 012P00101 2 11 Thermostat Adj 250 deg 290 deg F 032P00305 1 12 Thermostat Hi limit 032P00306 2 13 Heating Element 208V 1600W 015P00105 2 14 Fan Blade 5 16 Bore 013P00104 2 15 Caster 5 Swivel 011P00215 2 16 Caster 5 Swivel w Brake 011P00216 2 17 Dispenser Spring 063P00103 20 18 Dispenser Bushing 054P00502 8 19 Dispenser Assemb...

Page 10: ...10 DALPH1022 Exploded View Drawing ...

Page 11: ...11 Dispenser Assembly Exploded View Drawing ...

Page 12: ...12 Wiring Diagram ...

Page 13: ...ermination points by having qualified service person remove the back panel from the cabinet Make sure the cord sheathing extends into the cabinet interior If wires are showing on the outside of the cabinet remove the unit from use and have repairs made before turning on power to the unit Dispensing Mechanism 1 Periodically check springs for proper dispensing by filling each cavity with pellets pla...

Page 14: ...subject to abuse or misuse damage through no fault of ALLIANCE or its employees or altered by someone other than ALLIANCE or its authorized agents This warranty is exclusive and in lieu of all other warranties express or implied or statutory including the implied warranties of merchantability and fitness In no event shall ALLIANCE be liable for any delay in the performance of this warranty due to ...

Page 15: ...cretion replace any or all returned items within a reasonable time after Alliance determines that the returned goods are not in accordance herewith and in such event Alliance shall not be liable for any damage arising from the defective delivery or delay caused thereby When expressly authorized by Alliance in writing unused products may be returned to Alliance subject to service handling restockin...

Reviews: