74
|
P a g e
ELECTRICAL
(CONTINUED)
Inverter
Troubleshooting
(Continued)
o
If
using
the
remote
display
model,
make
sure
that
it
is
connected
to
the
inverter
using
the
provided
cable
The
inverter
has
turned
off
for
seemingly
no
reason
–
An
interruption
in
the
communication
between
the
display
and
the
inverter
has
taken
place.
o
Check
to
make
sure
that
the
equipment
ground
wire
is
properly
secured
to
the
ground
lug
The
inverter
is
making
a
buzzing
noise
–
A
buzzing
sound
may
sometimes
be
present
during
large
surges
in
output
power.
This
will
most
commonly
take
place
when
a
refrigerator
compressor
is
starting
up,
this
is
normal
and
will
not
last
more
than
2
seconds.
Inverter
Specifications
Physical
Dimensions
o
Length
–
11.6”
o
Width
–
10.6”
o
Height
–
4.0”
o
Weight
–
7lbs
Transfer
Switch
o
Transfer
voltage
–
100
volts
AC
o
Transfer
time
‐
<
50msec
o
Pass
Through
Ampacity
–
15
AAC
AC
Output
o
Output
voltage
–
120
volts
AC
o
Continuous
output
power
–
1000
W
o
Peak
output
power
–
2000
W
o
Frequency
–
60
Hz
o
Waveform
–
Pure
Sine
Wave
o
Peak
Efficiency
–
90%
DC
Input
o
Undervoltage
shutdown
–
10.5
volts
DC
o
Undervoltage
restart
–
12
volts
DC
o
Overvoltage
shutdown
–
15.5
volts
DC
o
Overvoltage
restart
–
15
volts
DC
o
Nominal
voltage
–
12
volts
DC
o
Nominal
current
@
max
load
–
100
ADC