Igniter Glows but Burner Does Not Ignite (Gas Dryer Models)
Did flame sensor fail
in closed position?
Is secondary coil or
holding coil open?
No
Replace sensor.
Yes
Is gas supply
insufficient?
No
Replace gas valve
coils. Refer to Dryer
Test Procedures
section
Yes
Are igniter and
bracket improperly
installed on burner
tube assembly?
No
Check gas supply and
pressure. Make sure
gas shutoff valve is
turned on.
Yes
Is sensor improperly
installed on burner
housing?
No
Loosen screw and
properly position
igniter and bracket
on burner tube
assembly.
Yes
Loosen screw and
properly position the
sensor on the burner
housing.
Yes
Dryer Troubleshooting
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
25
Part No. D515519R3
Summary of Contents for BD3NGBGS303EW01