Display
Description
Cause/ Corrective Action
E id
Board ID
Incorrect replacement control. Replace
user control or output board with correct
part.
E dS
Brownout/Voltage Configuration
Unexpected supply voltage. Check the har-
ness connections between the user control
and the output board. If the user control
was replaced, set dipswitch #1 to the same
setting as the previous control. If rework-
ing the machine to use a different supply
voltage, the dip switch #1 setting may
need to be changed.
If the dip switch #1 setting is changed,
power down, power up and try again.
E nr
Output Board Not Ready
Hardware failure. Replace output board.
E bS
Output Board Communication
Hardware failure. Replace output board.
EnXX
Machine ID
Communication failure. Power down,
power up and try again. If error persists,
check connection between user control and
Machine ID chip, or try replacing the user
control or the Machine ID chip.
E Co
Output Board Communication
Communication failure. Power down,
power up and try again. If error persists,
check connection between user control and
output board, or try replacing the user con-
trol or the output board.
E 59
Door Input Acquisition
Hardware failure. Replace output board.
E 60
Centrifugal Switch Input Acquisition
Hardware failure. Replace output board.
E 61
High Limit Thermostat Input Acquisition
Hardware failure. Replace output board.
E ro
Locked Rotor
The motor is not sensed as rotating when it
should be. Check that nothing is obstruct-
ing motor rotation, check connection be-
tween user control and output board, or try
replacing the user control or the output
board.
E nS
Motor Output Shorted
Hardware failure. Replace output board.
Table 1
Electronic Control Troubleshooting
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
36
Part No. D515519R3