Dryer Stops in Cycle; Quits After the First Few Loads; Has a Burning Smell;
Cycles on Motor Thermal Protector
Is voltage incorrect?
Is clothes load too
large?
No
Refer to serial plate
in door well for
correct voltage.
Refer to Installation
Instructions
(supplied with unit)
for electrical
requirements.
Yes
Is clothes cylinder
binding?
No
Remove part of load.
A normal washer load
is a normal dryer
load. Maximum load:
dryer cylinder one
half full of wet
clothes.
Yes
Is there broken,
loose or incorrect
wiring?
No
Check: cylinder for
binding and "out of
round" condition,
front and rear
bulkheads for
warping, support
rollers for binding,
cylinder seals and
glides for wear or
damage, and clothes
lodged between
cylinder baffle and
bulkhead.
Yes
Are motor switch
functions inoperative?
No
Refer to wiring
diagram.
Yes
Is there a short in
motor winding?
No
Refer to Adjustments
section to check
switch and windings.
Yes
Is a clothes item
caught in fan?
No
Refer to Adjustments
section to check
switch and windings.
Yes
Check fan for
obstruction.
Yes
Dryer Troubleshooting
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
16
Part No. D515519R3
Summary of Contents for BD3NGBGS303EW01
Page 2: ......