Error Codes
Display
Description
Cause/Corrective Action
EC19
No Card Reader
Communication
Communication failure. Power down, power up and try again. If error persists, replace
control or card reader.
Right most decimal
point Lit
Network Communi-
cation Error
Communication problem. Wait for 1.5 minutes for error to clear. If error doesn’t clear,
power-down and power-up the machine. If error persists, replace control or network
board.
Right most decimal
point Lit
Water Leak Detec-
tion Error or Slow
Drain Detection Er-
ror
Water leak test has detected a water leak during a cycle or slow drain is detected in the
drain step of a running cycle. The decimal point will remain lit after the error display
has expired. Clear the decimal point by pressing the START keypad three times within
five seconds or by cycling the power to the machine.
Right most decimal
point blinking
Machine ID Error
Machine ID is no longer communicating with the control. Check Machine ID connec-
tion.
ALArn
Break-in Alarm Er-
ror
Check the service door and coin vault switches.
oFF
Break-in Alarm
Shutdown Error
Check the service door and coin vault switches.
E FL
Fill Error
Fill level is not reached within 30 minutes (or other programmed length of time) in any
fill step.
E dL
Door Lock Fatal Er-
ror
Door is unlocked during a running cycle. To clear this error, cycle power to the ma-
chine.
E dL1
Door Lock Non-Fa-
tal Error
If the door fails to lock in twenty (20) seconds in Door Locking Mode after the Drive
has been enabled the control will turn off all outputs and show the error
E dL1
. To
clear this error the door must either open or lock.
E dL2
Door Unlock Non-
Fatal Error
If the door fails to unlock in 20 seconds, with a solenoid type door lock, after the drum
has stopped spinning, and all other outputs have been turned off, the control will show
error
E dL2
. To clear this error the door must unlock or open.
E door
Door Opened Dur-
ing A Running Cy-
cle
Control detects door open and door locked inputs high. Can be caused by pulling on
door while locked or about to lock. Correct inoperative door locking system. Unpower
machine to clear error.
E Ub1
Non-Fatal Unbal-
ance Error
Unable to balance load. Redistribute load and run cycle.
E Ub2
Fatal Unbalance Er-
ror
Wires to unbalance switch broken or not connected.
CLoSE door
Door Open Indica-
tor
Door is not closed during an active cycle. If door is closed, check for improper wiring
or faulty door switch.
Coin Error
Coin Error
Invalid coin pulse or inoperative coin sensor. Check coin drop area and remove obstruc-
tions. If error persists, tampering may have occured. Evaluate security procedures.
E id
Board ID
Incorrect replacement control. Replace user control or output board with the correct
part.