Error Codes
Display
Description
Cause/Corrective Action
E dS
Brownout/Voltage
Configuration
Unexpected supply voltage. Check the harness connections between the user control
and the output board. If the user control was replaced, set dip switch #1 to the same
seting as the previous control. If reworking the machine to use a different voltage sup-
ply, the dip switch #1 setting may need to be changed. If the dip switch #1 setting is
changed, power down, power up and try again.
E nr
Drive/Output Board
Not Ready
Hardware failure. Try cycling power to machine before replacing output board.
E bS
Drive/Output Board
Shorted
Hardware failure. Try cycling power to machine before replacing output board.
En
Machine ID Errors
En 31
Product Byte #1
Mis-Match
Product family does not match between the Machine ID Control and Front End Control.
Replace Machine ID Control with one meant for current Front End Control platform.
En 32
Product Byte #2
Mis-Match
Machine type does not match between the Machine ID Control and Front End Control
(frontload washer vs. dryer). Replace Machine ID Control and/or front end control with
one meant for current machine type.
En 33
Product Byte #3
Mis-Match
Control level does not match between the Machine ID Control and Front End Control
(A4 vs. A2). Replace Machine ID Control with a properly configured A level for the
control being attached. Use Factory Test Procedure to determine front end control’s
control level.
En 39
Corrupted Data on
Machine ID Control
Try cycling power to machine. If error continues, check for damage to Machine ID
Control and harness and/or replace Machine ID Control with a correctly configured
Machine ID Control.
En 3E
Machine control
cannot be config-
ured with the Ma-
chine ID Control in
the machine
Try cycling power to machine. If error continues, check for damage to Machine ID
Control and harness and/or replace Machine ID Control with a correctly configured
Machine ID Control.
En 3F
Cannot communi-
cate with the Ma-
chine ID Control
Try cycling power to machine. If error continues, check for damage to Machine ID
Control and harness and/or replace Machine ID Control with a correctly configured
Machine ID Control.
E Co
Drive/Output Board
Comunication Error
Communication failure. Power down, power up and try again. If error persists, check
connection between user control and output board, or try replacing the user control or
the output board.
E dr
Drain Error
If the control has the drain error enabled the control will enter Machine Error Mode
when the water height is not below the empty level, after attempting to drain for the
programmable time (default 15 minutes). In the event of a drain error, the control will
turn off all outputs and turn on the Machine Error Tone for 15 seconds.
E Sd
Slow Drain Error
If a slow drain is detected in the Drain step of a running cycle, the machine control will
light the right-most decimal point. The decimal point will remain illuminated after the
slow drain error display has expired, to draw the attention of the owner or attendant.
The decimal point can be cleared by pressing the START keypad 3 times in a period of
5 seconds, or by cycling the power to the machine.
Table continues...
Error Codes
©
Published by permission of the copyright owner -
DO NOT COPY or TRANSMIT
112
Part No. 805405ENR5
Summary of Contents for BT3JGASG403UW01
Page 2: ......