Error Codes
Display
Description
Cause/Corrective Action
E d 25
IPM Over Tempera-
ture Error
IPM temperature is detected to be too high. Check that drum spins freely when empty,
check for overloading of machine, reduce agitation time, and duty cycle if rotate/pause
times are very short and programmable. Unpower to clear error. Check for lint build-up
on heat sink on drive board. Replace drive board if error persists.
E d 29
Motor Not Connec-
ted Error
The motor or one of its electrical phases is not connected. Check that the harness from
the motor to the drive board is fully plugged in on both ends and that there is no dam-
age to the motor harness. Make sure to push in the motor harness on both ends just in
case it is a little loose and not fully inserted. If the harness looks fine and the error still
occurs, try replacing the drive board or harness. Unpower to clear error.
E d 44
Overcurrent Shunt
Detection Circuit
Fail Error
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 45
Door Lock Pin HW
On/Off Fail Error
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 46
Heater Pin HW
On/Off Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 47
Hot Valve Pin HW
On/Off Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 48
Cold Valve Pin HW
On/Off Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 49
Detergent Valve Pin
HW On/Off Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 50
Softener Valve Pin
HW On/Off Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 51
Inrush Pin HW
On/Off Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 52
Voltage Doubler Pin
HW On/Off Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 53
Door Lock Select
Voltage Pin HW
On/Off Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 54
Pump Pin HW
On/Off Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 55
Fatal NTC Short Er-
ror
Check heater thermistor and thermistor wiring for damage. Unpower to clear error. Re-
place drive board if error persists.
E d 56
Fatal NTC Open Er-
ror
Check heater thermistor and thermistor wiring for damage. Unpower to clear error. Re-
place drive board if error persists.
E d 63
Fatal IPM Tempera-
ture Short Error
Hardware failure. Unpower to clear error. Replace drive board if error persists.
Table continues...
Error Codes
©
Published by permission of the copyright owner -
DO NOT COPY or TRANSMIT
115
Part No. 805405ENR5
Summary of Contents for BT3JGASG403UW01
Page 2: ......