Rapid Advance Feature
This feature allows the user to quickly advance through an active
cycle or advance into a cycle from the Ready Mode. This feature
is useful when tests must be performed immediately on a ma-
chine currently in an active cycle. In this case, the user can quick-
ly advance through the cycle to the Ready Mode. At this point,
the user can perform the required tests and then return the ma-
chine to the active cycle.
How to Enter Rapid Advance
1. Control must be in Manual Mode. Refer to
2. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to scroll through the programmable options until
rAPid
appears in the display.
3. Press the START (enter) keypad. The display will show
PUSH
then
StArt
followed by the cycle time and the START (en-
ter) keypad LED will flash.
4. Press the START (enter) keypad to start cycle or, if already in
an active cycle, pressing START (enter) keypad will advance
to the next cycle step.
NOTE: Door must be closed to start cycle.
5. Continue pressing the START (enter) keypad until the cycle is
completed.
NOTE: The Rapid Advance option must be turned
on for Rapid Advance to work.
How to Exit Rapid Advance Feature
Advance through the cycle until reaching the Ready Mode.