Closing Washer Door
If the door is not closed when the vend price is satisfied,
CLoSE
and
door
will be displayed until the door is closed. Once door is
closed, the START pad must be pressed to lock door and start the
cycle. If the door does not lock within 20 seconds of being
closed,
E dL1
will be displayed, indicating a door lock error,
while the door continues to try to lock.
If the door locks after 20 seconds, the door lock error will clear
and the cycle will continue normally. The door can be opened to
clear the door lock error as well.
Signals
There are five options when a signal can be used during the
washer operation. These five options are listed below:
1.
End of Cycle Signal
By default, this signal is turned off. If
turned on, the signal sounds for three (3) seconds at the end of
a cycle.
2.
Signal On Keypad Depression
By default, this signal is
turned on and sounds for a quarter of a second each time a
keypad is pressed.
3.
Signal On Coin Input/Card Insertion
By default, this signal
is turned on and will sound for a quarter of a second each time
a coin or card is entered.
4.
Signal for Serial or Network Vending Command
By de-
fault, this signal is turned on for a quarter of a second when
the control receives a valid serial or network vend command.
5.
Signal for Start
By default, this signal is turned on and will
sound one (1) second on and one (1) second off for 10 sec-
onds after vend price has been satisfied.
NOTE: Refer to
options.
Changing Cycles
Cycles and wash temperature can be changed before the first fill
is complete. After the first fill, all key presses are ignored.
Selecting a higher priced cycle/wash temperature or modifier will
pause the first fill step, and INSERT COINS/CARD LED will
flash one (1) second on and one (1) second off until the vend
price has been satisfied. After the vend price has been satisfied,
the cycle will continue with the new selections. If the vend price
is not satisfied within one (1) minute, the washer control will go
back to the previously set cycle/wash temperature and modifier.
Pause Mode
Pause Mode is entered when the START pad is pressed three
times within 5 seconds during the first 3 minutes of a running
machine cycle. This mode is only manually accessible if the
Pause/Resume Mode (Enable/Disable) parameter is programmed
to Enabled and if the control is in Run Mode or Door Locking
Mode.
If this mode is entered the control will pause the cycle, enter
Door Unlocking Mode, and drain/pump the water out. After the
machine is confirmed to be empty and not rotating, the control
will unlock the door. The control will then enter Pause Mode.
The user may then restart the machine by pressing the START
pad, where the machine will enter Door Locking Mode and once
the door locks, the cycle will resume from where it left off.
NOTE: The display will show
PUSH
and
StArt
, the Cy-
cle Selection LEDs will be lit, and if the door is locked,
the door lock LED will be lit.
Delayed Start Setup (OPL Only)
Delayed Start Setup Mode is entered by holding any key except
for the START key for 5 seconds while in Start Mode. To prevent
changing the selected cycle and options, the user should press
and hold one of the actively selected keys.
The door must be closed in order to enter this mode.
This mode is only manually accessible if the Delayed Start Mode
(Enable/Disable) parameter is programmed to Enabled. While in
the Delayed Start Setup Mode, pressing the NORMAL 40 (
∧
) or
the DELICATES COLD (
∨
) keypads will alter the number of
hours the cycle is delayed up to a maximum of 72 hours. The
time will loop around when the maximum or minimum value is
reached. The display will show
XX HrS
while modifying time or
01 Hr
if 1 hour is set and this display will toggle 1 second on
and 1 second off.
If the door is opened while trying to program the delayed start
time, the control will exit this mode and go back to Start Mode.
Delayed Start (OPL Only)
Delayed Start is entered by pressing the Start keypad while in
Delay Start Setup Mode. This mode is only manually accessible
if the Delayed Start Mode (Enable/Disable) parameter is pro-
grammed to Enabled. The OPL Delay Start programming param-
eter can be programmed through IrDA and Network commands.
The display will show
XX HrS
toggled with
dELAy
every 1 sec-
ond while counting down the hours. The display will show
XX
Nin
toggled with
dELAy
every 1 second once the time is 1 hour
or less (would transition from
02 HrS
to
60 Nin
). The display
will count down one hour or minute at a time showing a leading
zero for one digit numbers.
Once the countdown time has expired or if the Start key is press-
ed while counting down delayed start time, the control will enter
Door Locking Mode to begin the cycle. Cycle selection related
LEDs will be lit while in this mode.
This mode can be exited by pressing the Back keypad which will
then place the control into Start Mode.
Washer Operation
©
Published by permission of the copyright owner -
DO NOT COPY or TRANSMIT
16
Part No. 805405ENR5
Summary of Contents for BT3JGASG403UW01