If the door is opened at any point while in this mode, Delayed
Start Mode will be exited and the control will enter Start Mode.
Auto Flush Mode
The Auto-Flush Mode is only available if enabled in the Control
Configuration. The programmable Auto-Flush option allows the
control to be set to automatically flush the dispenser compart-
ments at predetermined intervals and times. The option may be
enabled or disabled. Auto Flush is entered if the following condi-
tions are met.
1. It must be enabled in the Progamming Parameters.
2. The machine is in Ready Mode, Start with OPL Mode Active
and not in Power Recovery, or Shut-Down Mode with the door
closed.
3. The pre-programmed number of cycles have occurred since the
last Auto-Flush.
4. The current day-of-week matches the programmed day-of-
week.
5. The current hour matches the programmed hour.
If these conditions are met, then the control will flush the dis-
penser compartments with hot water for a pre-programmed num-
ber of seconds (factory default is 30 seconds) or until the pressure
sensor senses water up to the door level.
Overflow Mode
If the control isn’t running a cycle, is not in Door Locking Mode
or Door Unlocking Mode, the overflow level is set at 6 inches. In
Overflow Mode, if the door is closed, the door will lock, the
pump will turn on, and the gravity drain will open until the water
level is below the overflow reset level if running a cycle, other-
wise the machine will drain until the drum is seen empty.
If Overflow Mode Display is disabled and the control will enter
Run Mode when it exits, the display will show the default Run
Mode display, otherwise in all other cases, the display will show
oFLo
. If the door locks and the overflow level is no longer being
met within five (5) minutes of first detecting the overflow, the cy-
cle will continue as normal and the control will go back to the
mode it was previously in. If the control continues to see an over-
flow error after five (5) minutes has been reached with the door
locked, the control will enter Machine Error Mode with an Over-
flow Error.
Lockout Mode
If enabled in the Control Configuration, Lockout Mode is entered
to prevent the machine from being used except by a particular
user who has reserved the machine in advance. This mode is en-
tered when the current time (in Hours and Minutes) falls within
the time period set by the Lockout Mode Start Time Hour, Lock-
out Mode Start Time Minute, Lockout Duration, and when the
control is in Ready Mode. The display will show
rES
. User ac-
cess is ignored until Lockout Mode is exited. The control will be
able to communicate with the Network, IR, or the Serial Payment
System.
When entering the sequence of keypresses to exit Lockout Mode,
pressing the START keypad signals the end of the keypress se-
quence. As each keypad is pressed the corresponding LED is lit.
Anytime the START keypad is pressed the correct number of
keys entered is verified and if not equal to four (4) the keypad se-
quence will be reset, all LED’s will be turned off, and keypresses
will be ignored for five (5) seconds while remaining in Lockout
Mode. In addition, if five (5) keypads are pressed before the
START keypad is pressed, the sequence will be reset, all LED’s
will be turned off, and keypresses will be ignored for five (5) sec-
onds while remaining in Lockout Mode.
When the correct sequence of keypresses has been entered the
control will enter Ready Mode. If the network programs the dura-
tion to zero, Lockout Mode will be exited.
Shutdown Mode
Shutdown Mode is entered if a Low Power/Shutdown Option (1,
2, 3, or 4) becomes active with the Shutdown option enabled. To
become active, the Low Power/Shutdown Option must be ena-
bled in the Control Configuration and the current time, day-of-
week, date, month, and year must match the programmed start re-
quirements for the triggering Low Power/Shutdown Option.
If the control is in ready mode, drop-off mode, lockout mode, or
start mode when no vend has been entered, shutdown mode can
be entered. Shutdown Mode will automatically exit if the current
time, day-of-week, date, month, and year satisfy an exit condition
for the active Low Power/Shutdown Option. While in Shutdown
Mode, the control will show
oFF
and all LEDs will be turned off.
Shutdown Mode can be exited by disabling the triggering Low
Power/Shutdown Option (1, 2, 3, or 4) through Network and Ir-
DA commands. In addition, the Low Power/Shutdown Option (1,
2, 3, or 4) can be disabled using manual programming.
Power Failure Display Mode
In Power Failure Display Mode the control will show
PrFAiL
.
This informs the user that a cycle was interrupted and did not
complete normally. This mode is entered from Power-Up Mode if
a power failure occurred during an OPL cycle and the cycle is not
able to automatically resume. If the user presses any key, Start
Mode is entered.
Washer Operation
©
Published by permission of the copyright owner -
DO NOT COPY or TRANSMIT
17
Part No. 805405ENR5