Special Features
Programming Control
The control allows the owner to program the control with the use
of the keypad. Cycle and vend information may be programmed,
audit information may be viewed and diagnostic tests may be run
by pressing keypad combinations.
Collecting Audit Information
The control stores audit information in its memory that can be re-
trieved by pressing various combinations of Select Cycle pads.
For more information on the audit features, refer to
NOTE: Additional audit information is retrievable with
an external device, the card reader and the network.
Refer to the appropriate instruction manual.
Testing Machine and Control Functions
Special diagnostic features built into the control allow the owner
to run specific diagnostic tests. By opening and closing the serv-
ice door and then pressing various sequences of Select Cycle
pads, the owner may perform the following tests:
• Control Software Version # Test
• Drive Board #1 Software Version Test
• Water Level Trim Test
• Service Door Switch Input Test
• Coin Vault Switch Input Test
• Coin Drop #1 Input Test
• Coin Drop #2 Input Test
• Vend Connection Header Present Input Test
• Start Pulse Input Test
• Door Switch Input Test*
• Door Lock Switch Input Test*
• Show Fill Time Test
• Show Drain Time Test
• Temperature Sensor Display Test (Heater/Temp Sensor only)
• Out of Balance Switch Input Test
• External Output Test*
• Water Purge Test*
• Water Leak Detection Test*
• Water Level Test
• DC Bus Voltage Test
• AC Mains Voltage Test
• Machine Configuration #1 Display Test
• Machine Configuration #2 Display Test
• Machine Configuration #3 Display Test
• Machine Configuration #4 Display Test
• Machine Configuration #5 Display Test
* Tests can only be entered when in Start or Ready Mode.
For detailed information on running diagnostic tests, refer to
ing Machine and Electronic Control Functions
Rapid Advance Feature
This feature allows the user to quickly advance through an active
cycle or advance into a cycle from the Ready Mode. This feature
is useful when tests must be performed immediately on a ma-
chine currently in an active cycle. In this case, the user can quick-
ly advance through the cycle to the Ready Mode. At this point,
the user can perform the required tests and then return the ma-
chine to the active cycle.
Clearing the Vend Feature
This feature allows the user to return the control back to the
Ready Mode if coins have been entered but the full vend price
has not yet been satisfied, while in Partial Vend Mode.
For more information on using the Clear Vend feature, refer to
Communications Mode
This feature allows the machine control to communicate with an
external device, the card reader, or the network. This allows the
washer control to be programmed and have its data read without
using the keypad.
For more detailed information on using the Communications
Mode feature, refer to
.
Coin Drop
The control will accept pulses from a single or dual coin drop to
satisfy vend price. Each coin drop will have the ability to satisfy
the vend.
Start Pulse Operation
The control will accept pulses from optional payment systems.
The machine can be programmed to receive a single start pulse or
multiple start pulses, or the Start Pulse Option can be turned off.
The Start Pulse Mode allows the machine to go from the Ready
Mode to the Start Mode after a single or multiple pulses are re-
ceived.
Special Features
©
Published by permission of the copyright owner -
DO NOT COPY or TRANSMIT
18
Part No. 805405ENR5
Summary of Contents for BT3JGASG403UW01
Page 2: ......