Network Node Number
nodE
This option allows the owner to program a unique number used
for wired or wireless communication. Every machine on the same
network much have a different node number to work correctly.
1. Control must be in Manual Mode. Refer to
2. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad until
Prog
appears in the display. Press the START
(enter) keypad, and
AtS 1
will appear in the display.
3. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to scroll through the programmable options until
nodE
appears in the display.
4. When
nodE
appears in the display, press the START (enter)
keypad. The current Network Node Number status will appear
in the display.
5. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Error Code Programming
Error-
This option allows the owner to turn on or turn off certain errors
in the control.
1. Control must be in Manual Mode. Refer to
2. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad until
Prog
appears in the display. Press the START
(enter) keypad, and
AtS 1
will appear in the display.
3. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to scroll through the programmable options until
Er-
ror-
appears in the display.
4. When
Error-
appears in the display, press the START (en-
ter) keypad. There are multiple programmable error code pa-
rameters. Refer to
5. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to select the desired option.
6. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to select error code.
7. Press the START (enter) keypad when the correct code ap-
pears in the display. The current status will appear in the dis-
play.
NOTE: Press the NORMAL 40 (
∧
) or the DELICATES
COLD (
∨
) keypad and then the START (enter) keypad
again to choose a specific coin error parameter. Re-
fer to
8. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to change the status.
9. Press the START (enter) keypad when the correct status ap-
pears in the display. The next Error Code Programming op-
tion will appear in the display.
Error Code Programming
Error-
CErr-
Coin Error Parameters Menu
CEr 1
Coin Error - Determines if display will
show error.
CEr 2
Coin Error Penalty - If enabled, coin er-
ror will erase previous coins entered and
reset the vend price.
CEr 3
Vend Header Present Error - If enabled
and coin drop header is unplugged, con-
trol ignores coin inputs.
Table 5