Error Code Programming
Error-
E FL-
Fill Error Menu
E FL 1
Fill Error (On/Off) - If Enabled, will set
error after fill error alarm time if fill level
isn't reached, if disabled will allow filling
forever if fill level never reached.
E FL 2
Fill Error Time - Time allowed in mi-
nutes to reach target fill level before set-
ting a fill error.
E nF-
No Water Flow Error Menu
E nF 1
No Water Flow Error (On/Off) - If Ena-
bled, will set error after no water flow er-
ror time if 4 inch water level isn't
reached. If disabled will allow filling for-
ever until 4 inch level is reached.
E nF 2
No Water Flow Error Time - Time al-
lowed in minutes to reach a 4 inch fill
level.
E Hd
E Hd
Too Hot to Drain Error (Heater/Temp
Sensor only) - If water is too hot to drain
safely during a Drain or Extract step, the
control will display this error at the end
of the cycle after the door is opened or a
key is pressed and will continue to show
the error until any key has been pressed
or for one minute. Cool Down steps
should be added if this error occurs often
to prevent this error and improve cycle
operation.
E dr-
Drain Error Menu
E dr 1
Drain Error (On/Off) - If Enabled, will
set error after drain error alarm time if
empty water level isn't reached, if disa-
bled will allow draining forever if empty
level never reached.
E dr 2
Drain Error Time - Time allowed in mi-
nutes to reach an empty water level be-
fore setting the drain error.
Table 5
continues...
Programming Control
©