Error Code Programming
Error-
SUd-
Suds Removal Routine Menu
SUd 1
Suds Removal Routine Display (On/Off)-
Will show "SUdS" on the display while a
Suds Removal Routine is being per-
formed during the cycle.
SUd 2
Suds Removal Routine Allowed Per Cy-
cle - Allows the owner to pick how many
Suds Removal Routines are allowed per
cycle.
SUd 3
Suds Removal Routine Extra Time (On/
Off) - If programmed to ON, the Suds
Removal Routines will pause cycle time
to perform suds removal routines, if Off,
the Suds Removal Routines will use cy-
cle time which may result in poorer ma-
chine performance.
ovrFLd
ovrFLd
Overflow Mode Display - Can be used to
disable "oFLo" on the display while in an
Overflow Condition during a running cy-
cle if set to Off. In all other modes, it will
always show "oFLo" if an overflow con-
dition exists.
CLrErr
CLrErr
Allow Error Clearing (On/Off) - Allows
the ability for the owner to clear most er-
rors by pressing NORMAL 90 NOR-
MAL 60 keypads. Some errors will still
require power to be cycled to clear the er-
ror and some errors will continually set
themselves until the condition for the er-
ror being set is fixed. Call for service if
an error will not clear.
Table 5
Temperature (Fahrenheit/Celsius)
(Heater/Temp Sensor only)
tP F C
This option allows the owner to set whether the display units for
temperature will be shown in Fahrenheit or Celsius.
1. Control must be in Manual Mode. Refer to
2. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad until
Prog
appears in the display. Press the START
(enter) keypad, and
AtS 1
will appear in the display.
3. Press the NORMAL 40 (
∧
) or the DELICATES COLD(
∨
)
keypad to scroll through the programmable options until
tP
F C
appears in the display.
4. When
tP F C
appears in the display, press the START (en-
ter) keypad. A setting will appear in the display. This setting
(found below) corresponds to the current Temperature (Fah-
renheit/Celsius) setting.
CELCiU
= Celsius
FAHrEn
= Fahrenheit
5. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to set the desired value.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.