2. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad until
Prog
appears in the display. Press the START
(enter) keypad, and
AtS 1
will appear in the display.
3. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to scroll through the programmable options until
FL
Lo
appears in the display.
4. When
FL Lo
appears in the display, press the START (enter)
keypad. A number will appear in the display. This number
corresponds to the current Water Level setting.
5. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Medium Water Level
FL NEd
This option allows the owner to set the medium water level
which can be used in fill steps to set water levels in cycle pro-
gramming.
1. Control must be in Manual Mode. Refer to
2. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad until
Prog
appears in the display. Press the START
(enter) keypad, and
AtS 1
will appear in the display.
3. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to scroll through the programmable options until
FL
NEd
appears in the display.
4. When
FL NEd
appears in the display, press the START (en-
ter) keypad. A number will appear in the display. This number
corresponds to the current Water Level setting.
5. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
High Water Level
FL Hi
This option allows the owner to set the high water level which
can be used in fill steps to set water levels in cycle programming.
1. Control must be in Manual Mode. Refer to
2. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad until
Prog
appears in the display. Press the START
(enter) keypad, and
AtS 1
will appear in the display.
3. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to scroll through the programmable options until
FL
Hi
appears in the display.
4. When
FL Hi
appears in the display, press the START (enter)
keypad. A number will appear in the display. This number
corresponds to the current Water Level setting.
5. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Flush Out Time for Fill Step
FLSH t
This option allows the owner to set the flush out time in seconds
for fill steps that have flush out enabled. The flush out is used to
help rinse out the machine at the beginning of the fill steps. The
water will be evacuated for the programmed time at the begin-
ning of the fill steps that have this option enabled.
1. Control must be in Manual Mode. Refer to
2. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad until
Prog
appears in the display. Press the START
(enter) keypad, and
AtS 1
will appear in the display.
3. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to scroll through the programmable options until
FLSH t
appears in the display.
4. When
FLSH t
appears in the display, press the START (en-
ter) keypad. A number will appear in the display. This number
corresponds to the current setting.
5. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
No Refill After Time for Agitate Step
norF t
This option allows the owner to set the no refill after time in mi-
nutes for fill, agitate, and soak steps. Refills can only occur if the
programmed time has not been exceeded in the current step.
1. Control must be in Manual Mode. Refer to
2. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad until
Prog
appears in the display. Press the START
(enter) keypad, and
AtS 1
will appear in the display.
3. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to scroll through the programmable options until
norF
appears in the display.
4. When
norF
appears in the display, press the START (enter)
keypad. A number will appear in the display. This number
corresponds to the current setting.
5. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Programming Control
©