3. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to scroll through the programmable options until
LUC-
appears in the display.
4. When
LUC-
appears in the display, press the START (enter)
keypad. There are three programmable Lucky Cycle options.
Refer to
.
Display
Lucky Cycle Options
LUC 1
Lucky Cycle Day(s) of
Week / Enable On/Off
for pro-
gramming.
LUC 2
Lucky Cycle Number
(0-255)
LUC 3
Lucky Cycle Display Op-
tion On/Off
ON = Free vend. Lucky
cycle active after 4.25 mi-
nutes in Ready Mode.
OFF = Vend must be en-
tered. Remaining vend is
free. For example, after
entering a coin the price
will count down by Coin
1 value until vend is satis-
fied.
Table 25
NOTE: When the Lucky Cycle conditions have been
met, the display will show
FrEE
when the Display
Option is set to On.
5. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Heating Indicator Decimal Point (Heat-
er/Temp Sensor only)
Ht dP
This option allows the owner to enable or disable the heating in-
dicator decimal point on the machine. If enabled, the left most
decimal point on the display will be lit anytime the heater is on
during a cycle.
1. Control must be in Manual Mode. Refer to
2. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad until
Prog
appears in the display. Press the START
(enter) keypad, and
AtS 1
will appear in the display.
3. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to scroll through the programmable options until
Ht
dP
appears in the display.
4. When
Ht dP
appears in the display, press the START (enter)
keypad. The current status will appear in the display.
on
= Option Enabled
oFF
= Option Disabled (factory default setting)
5. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Temperature Display
tP diS
This option allows the owner to program the temperature display.
If enabled, the user can display the water temperature reading
during an agitate or soak step by pressing the active cycle key-
pad. Further presses will toggle the display and the display will
also be exited upon exit of the step.
1. Control must be in Manual Mode. Refer to
2. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad until
Prog
appears in the display. Press the START
(enter) keypad, and
AtS 1
will appear in the display.
3. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to scroll through the programmable options until
tP
diS
appears in the display.
4. When
tP diS
appears in the display, press the START (en-
ter) keypad. The current Temperature status will appear in the
display.
on
= Option Enabled
oFF
= Option Disabled (factory default setting)
5. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Speed Units
SUnitS
This option allows the owner to program the speed units to be
shown in RPMs or G Force for all speed related programming pa-
rameters.
1. Control must be in Manual Mode. Refer to
2. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad until
Prog
appears in the display. Press the START
(enter) keypad, and
AtS 1
will appear in the display.
3. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to scroll through the programmable options until
SU-
nitS
appears in the display.
Programming Control
©
Published by permission of the copyright owner -
DO NOT COPY or TRANSMIT
91
Part No. 805405ENR5
Summary of Contents for BT3JGASG403UW01