Hot Water Temperature (Heater/Temp
Sensor only)
FL Hot
This option allows the owner to set the hot water temperature
which can be used to set fill temperature in cycle programming.
1. Control must be in Manual Mode. Refer to
2. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad until
Prog
appears in the display. Press the START
(enter) keypad, and
AtS 1
will appear in the display.
3. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to scroll through the programmable options until
FL
Hot
appears in the display.
4. When
FL Hot
appears in the display, press the START (en-
ter) keypad. A number will appear in the display. This number
corresponds to the current Water Temperature setting and is
displayed in Fahrenheit or Celsius based on the temperature
setting.
5. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Warm Water Temperature (Heater/Temp
Sensor only)
FL HC
This option allows the owner to set the warm water temperature
which can be used to set fill temperature in cycle programming.
1. Control must be in Manual Mode. Refer to
2. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad until
Prog
appears in the display. Press the START
(enter) keypad, and
AtS 1
will appear in the display.
3. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to scroll through the programmable options until
FL
HC
appears in the display.
4. When
FL HC
appears in the display, press the START (enter)
keypad. A number will appear in the display. This number
corresponds to the current Water Temperature setting and is
displayed in Fahrenheit or Celsius based on the temperature
setting.
5. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Cold Water Temperature (Heater/Temp
Sensor only)
FL CLd
This option allows the owner to set the cold water temperature
which can be used to set fill temperature in cycle programming.
1. Control must be in Manual Mode. Refer to
2. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad until
Prog
appears in the display. Press the START
(enter) keypad, and
AtS 1
will appear in the display.
3. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to scroll through the programmable options until
FL
CLd
appears in the display.
4. When
FL CLd
appears in the display, press the START (en-
ter) keypad. A number will appear in the display. This number
corresponds to the current Water Temperature setting and is
displayed in Fahrenheit or Celsius based on the temperature
setting.
5. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Cool Down Temperature (Heater/Temp
Sensor only)
CooLdn
This option allows the owner to set the cool down global water
temperature for cool down steps.
1. Control must be in Manual Mode. Refer to
2. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad until
Prog
appears in the display. Press the START
(enter) keypad, and
AtS 1
will appear in the display.
3. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to scroll through the programmable options until
CooLdn
appears in the display.
4. When
CooLdn
appears in the display, press the START (en-
ter) keypad. A number will appear in the display. This number
corresponds to the current Water Temperature setting and is
displayed in Fahrenheit or Celsius based on the temperature
setting.
5. Press the NORMAL 40 (
∧
) or the DELICATES COLD (
∨
)
keypad to change the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Low Water Level
FL Lo
This option allows the owner to set the low water level which can
be used in fill steps to set water levels in cycle programming.
1. Control must be in Manual Mode. Refer to
Programming Control
©
Published by permission of the copyright owner -
DO NOT COPY or TRANSMIT
56
Part No. 805405ENR5