FLW101R_SVG
"d 1"
Control Software
Version Number Test
"d 3"
Drive Board #1
Software Version Test
"d 7"
Water Level
Trim Test
"d 8"
Service Door Switch
Input Test
"d 9"
Coin Vault Switch
Input Test
"dIAg"
Diagnostic Tests
"d 10"
Coin Drop #1
Input Test
"d 11"
Coin Drop #2
Input Test
"d 12"
Vend Connection Header
Present Input Test
"d 13"
Start Pulse
Input Test
"d 15"
Door/Lid Switch
Input Test
"d 17"
Show Fill
Time Test
"d 16"
Door/Lid Lock Switch
Input Test
"d 18"
Show Drain
Time Test
"d 19"
Temperature Sensor
Display Test
"d 22"
Out of Balance Switch
Input Test
"d 23"
External Output Test
"d 24"
Water Purge
Test
"d 26"
Water Level Test
"d 27"
DC Bus Voltage Test
"d 29"
Machine Configuration #1
Display Test
"d 28"
AC Mains Voltage Test
"d 25"
Water Leak
Detection Test
"d 30"
Machine Configuration #2
Display Test
"d 31"
Machine Configuration #3
Display Test
"d 32"
Machine Configuration #4
Display Test
"d 33"
Machine Configuration #5
Display Test
Press the
START (enter)
keypad.
Press the
NORMAL 40 or
the DELICATES COLD keypad to
scroll through the
Diagnostic Test options.
To enter a test, press the
START (enter) keypad.
To exit a test, press the
DELICATES 30 keypad.
Figure 15
Diagnostic Test Descriptions
Control Software Version Number Test
d 1
This option displays the control software version number. To start
test, control must be in the Testing Mode. Refer to
at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
S XX
where
XX
is the software version number.
Testing Machine and Electronic Control Functions
©
Published by permission of the copyright owner -
DO NOT COPY or TRANSMIT
99
Part No. 805405ENR5
Summary of Contents for BT3JGASG403UW01