© Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
Electrical Requirements
70458301ENR6
66
21 kW 030 Series Electric Models
Table 14
21 kW T30 Series Electric Models
Table 15
Serial Plate Voltage
Terminal Block
Connections Required
Serial Plate Amps
Recommended Circuit
Non-
reversing
Reversing Breaker Rating
Wire Size
AWG (mm
2
)
208V/60Hz/1ph
L1, L2, Neutral, and ground
108
N/A
150A – 2 pole
1/0 (50)
240V/60Hz/1ph
L1, L2, Neutral, and ground
94
N/A
125A – 2 pole
1 (35)
200V/60Hz/1ph
L1, Neutral, and ground
108
N/A
150A – 1 pole
1/0 (50)
200V/50Hz/1ph
L1, Neutral, and ground
105
N/A
150A – 1 pole
1/0 (50)
230-240V/50Hz/1ph
L1, Neutral, and ground
95
N/A
125A – 2 pole
1 (35)
200-208V/60Hz/3ph**
L1, L2, L3, and ground
62
62
80A* – 3 pole
4 (25)
200V/50Hz/3ph**
L1, L2, L3, and ground
60
60
80A* – 3 pole
4 (25)
230-240V/50Hz/3ph**
L1, L2, L3, and ground
55
N/A
70A* – 3 pole
4 (25)
240V/60Hz/3ph**
L1, L2, L3, and ground
54
54
70A* – 3 pole
4 (25)
380V/50 or 60Hz/3ph**
L1, L2, L3, and ground
33
33
45A* – 3 pole
8 (10)
400-415V/50Hz/3ph**
L1, L2, L3, and ground
31
31
40A* – 3 pole
8 (10)
440V/60Hz/3ph
L1, L2, L3, and ground
29
N/A
40A* – 3 pole
8 (10)
460-480V/60Hz/3ph**
L1, L2, L3, and ground
27
27
35A* – 3 pole
8 (10)
*
3 Phase machines should not have fuses, breakers only.
** These serial plate voltages are only options available on the 30 series electric models.
N/A = Not Applicable
Serial Plate Voltage
Terminal Block
Connections Required
Serial Plate
Amps
Recommended Circuit
Breaker Rating
Wire Size
AWG (mm
2
)
200-208V/60Hz/3ph*
L1, L2, L3, and ground
62**
80A – 3 pole
4 (25)
200V/50Hz/3ph*
L1, L2, L3, and ground
60**
80A – 3 pole
4 (25)
230-240V/50Hz/3ph*
L1, L2, L3, and ground
55**
70A – 3 pole
4 (25)
240V/60Hz/3ph*
L1, L2, L3, and ground
54**
70A – 3 pole
4 (25)
380V/50 or 60Hz/3ph*
L1, L2, L3, and ground
33**
45A – 3 pole
8 (10)
400-415V/50Hz/3ph*
L1, L2, L3, and ground
31**
40A – 3 pole
8 (10)
440V/60Hz/3ph
L1, L2, L3, and ground
29**
40A – 3 pole
8 (10)
460-480V/60Hz/3ph
L1, L2, L3, and ground
27**
35A – 3 pole
8 (10)
*
These serial plate voltages are only options available on the T30 electric models. Current (Amp) is for one pocket only.
** Per heater on T30 electric models, each has two heaters.