TMB2282N_SVG
13
12
11
10 9
8
7
6
5
4
3
2
1
1.
Gas Valve
2.
Regulator Plate
3.
Burner Orifice
4.
Burner Tube Openings
5.
Burner
6.
Pressure Tap
7.
Spud Holder
8.
Manifold Pipe
9.
Anti-Torque Ring
10.
Spud Holder Nut
11.
Plate
12.
Gasket
13.
Regulator Cap
Figure 16
How to Adjust Gas Valve Governor/Regulator
1.
Check gas burner orifice (manifold) pressure as follows. Re-
fer to
Figure 16
.
2.
Remove screw plug from pressure tap.
3.
Connect a “U”-tube manometer (or similar pressure gauge) to
the burner orifice (manifold) pressure tap.
4.
Start tumble dryer and note pressure once flame is burning.
Remove regulator cap and adjust regulator screw until the
burner orifice pressure per applicable table is achieved. Re-
place regulator cap. Refer to
Figure 16
.
5.
Commission tumble dryer for use.