Model
Gas
Altitude
Burner Orifice
New
Rate
feet [me-
ters]
No.
inches
[mm]
Quantity
Part
Number
Btu/hr.
[Mj/hr.]*
050 Series
Natural Gas
2001-4000
[610-1220]
27
0.1440 [3.7]
2
M400998
119,600
[126]
4001-6000
[1221-1830]
28
0.1405 [3.6]
M401014
109,200
[115]
6001-8000
[1831-2440]
29
0.1360 [3.4]
M400997
98,800 [104]
8001-10,000
[2441-3050]
30
0.1285 [3.3]
M401021
88,400 [93]
L.P. Gas
2001-4000
[610-1220]
43
0.0890 [2.3]
M406184
119,600
[126]
4001-6000
[1221-1830]
44
0.0860 [2.2]
M401011
109,200
[115]
6001-8000
[1831-2440]
45
0.0820 [2.1]
M401027
98,800 [104]
8001-10,000
[2441-3050]
46
0.0810 [2.1]
M401003
88,400 [93]
Classic Line
075 Series
Natural Gas
2001-4000
[610-1220]
29
0.1360 [3.4]
3
M400997
151,800
[160]
4001-6000
[1221-1830]
30
0.1285 [3.3]
M401021
138,600
[146]
6001-8000
[1831-2440]
1/8
0.1250 [3.2]
M402489
125,400
[132]
8001-10,000
[2441-3050]
31
0.1200 [3.0]
M401017
112,200
[118]
L.P. Gas
2001-4000
[610-1220]
45
0.0820 [2.1]
M401027
165,000
[174]
4001-6000
[1221-1830]
47
0.0785 [2.0]
M400999
138,600
[146]
6001-8000
[1831-2440]
47
0.0785 [2.0]
M400999
125,400
[132]
8001-10,000
[2441-3050]
48
0.0760 [1.9]
M401001
112,200
[118]
Table 7
continues...
Gas Requirements
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
49
Part No. 70457901ENR12
Summary of Contents for YU050E