Wire Colors
Description
BLK wire
24V AC/DC from central pay
system
BLU wire
Common (negative) from cen-
tral pay system
GRY wire
Machine busy signal to central
pay system
Table continues...
Wire Colors
Description
BRN wire
Machine busy signal to central
pay system
Start Pulse Requirements
All control types will consider a pulse valid if it is between 200
and 1000 milliseconds in length, with a minimum of 200 milli-
seconds between pulses.
DX4 Control Only (3L or 3K Control Suffixes)
The DX4 control tumble dryer comes configured to operate at 24 Volts AC or DC. If the central pay system provides 200-240V AC,
conversion is possible. Loosen screw and move the BLK wire to the adjacent open terminal and tighten securely. Refer to
Figure 24
and
Figure 25
.
TMB2406N_SVG
BLK
BLU
GRY
BRN
1
1.
Move BLK wire here to configure control to accept 200-240 Volts from central pay system
Figure 24
1
2
3
VCC
COIN
COIN
COM
IN1
IN2
24V
24V
CP INPUT
MACHINE
BUSY
240V
OR
240V
COMMON
OUT
OUT
H1-P4 RED COIN 1
H1-P10 BLU COIN 2
H1-P5 WHT COIN 1
H1-P11 WHT COIN 2
H2-P8 PNK/BLK
H2-P10 WHT
CYCLUS
TMB2407N_SVG
1.
DX4 Control
2.
CP Board
3.
Central Pay System
Figure 25
Electrical Requirements
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
53
Part No. 70457901ENR12