© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
70458101 (EN)
28
B
asic Configuration
1. Determine the necessary conversion operations
to convert from the factory-supplied
configuration to the desired configuration.
2. Perform the conversions required so the machine
is properly configured for the desired country and
gas (refer to
Specific Conversion Procedures
section):
How to Convert Gas Valve from Regulated to
Unregulated
How to Change Burner Orifice Size
How to Adjust Gas Valve Governor/Regulator
3. If applicable, peel off the appropriate country
sticker (included with machine) and apply it to
the serial plate over the existing country
information.
4. If applicable, peel off the appropriate conversion
sticker (included with machine) and apply it to
the serial plate over the “ADJUSTED FOR
______ GAS: ______” information.
5. Commission tumble dryer for use.
Figure 7
Specific Conversion Procedures
How to Convert Gas Valve from Regulated to
Unregulated
NOTE: Conversion from regulated to unregulated
is only needed when regulated tumble dryers were
ordered, but unregulated tumble dryers were
needed.
1. Disconnect electrical power from tumble dryer.
Close gas shut-off valve to tumble dryer. Refer to
Figure 7
.
2. Follow instructions in Conversion Kit, Part No.
M400763 (Johnson Part No. Y71AA-5C).
NOTE: This kit does not contain any burner
orifices.
3. Replace burner orifice(s) as per
Table 2
.
4. Commission tumble dryer for use.
WARNING
When converting the tumble dryer to a
different gas or pressure, first verify that
the supply inlet pressure is equipped with
a pressure regulator (located ahead of the
tumble dryer) that will maintain the gas
supply at the inlet pressure specified.
W430R1
TMB2328N
1
Gas Shut-Off Valve (Ahead of pressure tap)
(Not Supplied)
2
Pressure Tap
3
Gas Shut-Off Valve (Shown in closed
position) (Not Supplied)
TMB232
SPECIFIED
LOCAL INLET
PRESSURE
3
2
1