© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Steam Requirements
51
70458101 (EN)
170 and 200 Series Tumble Dryers
Figure 20
TMB2024N
NOTE: Refer to
Table 14
for sizing of steam lines. Piping must also be sized accordingly for length of runs and
number of elbows.
1
Risers 305 mm
(12 in.)
6
457 mm Drop (18 in.)
2
Shut-Off Valve
7
Steam Bonnet
3
Check Valve
8
Solenoid Valve (Supplied with machine)
4
Vacuum Breaker (optional)
9
Union
5
Condensate Return Line from Supply Line
10
Trap with Built-In Strainer
TMB2024N
SUPPLY
2
1
9
3
RETURN
2
3
7
10
4
5
8
6
Steam Pressure bar
(PSI)
Minimum
Supply Pipe Diameter
Steam Trap Size *
Kilograms Condensate/Hour
(Pounds Condensate/Hour)
5.3-6.9 (80-100)
1-1/4 in. NPT
235 (517)
* Based on maximum bar.
Table 14