Error Codes
Display
Definition
Corrective Action
OP
Open thermistor error
Check thermistor. Replace if inoperative.
Check wiring diagram between control and
thermistor. Refer to wiring diagram for proper
wiring.
Check control. Replace if inoperative.
SH
Shorted thermistor error
Check thermistor. Replace if inoperative.
Check wiring between control and thermistor. Refer
to wiring diagram for proper wiring.
Check control. Replace if inoperative.
AF - 1
Airflow switch closed when cycle
started
Check airflow switch. Replace if inoperative.
AF - 2
Airflow switch failed to close after cycle
started
Check airflow switch. Replace if inoperative.
AF
(Flashing)
Bouncing Airflow Switch
Check airflow switch to ensure that it is properly
aligned and securely mounted in the mounting
bracket.
Make sure airflow switch can open and close freely.
Check installation and make sure there is adequate
airflow.
Make sure exhaust is not blocked.
Clean the lint screen.
Replace airflow switch if inoperative.
AF
(Solid)
Airflow Switch Closed when Resuming
Cycle
Allow up to 20 seconds for this condition to clear.
Check if airflow switch opens at end of cycle.
Replace airflow switch if inoperative.