© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Maintenance
73
70458101 (EN)
Monthly
1. Remove lint and debris from inside exhaust duct
to maintain proper airflow and avoid
overheating.
a. Remove external duct and duct access covers,
if present.
b. Clean inside of duct with a vacuum.
c. Clean dampers and make sure they operate
freely.
2. Ensure even lint distribution over lint screen.
3. Carefully wipe any accumulated lint off the
cabinet high limit thermostat and thermistor,
including perforated cover.
4. Clean lint and debris buildup from blower to
maintain proper airflow.
Quarterly
1. Use a vacuum to clean air vents on drive motors.
2. Use a vacuum to clean lint from rear limit
thermostat cover.
3. Check and clean steam coils, if applicable.
4. Check flow of combustion and ventilation air.
5. Check belt tension and condition. Replace worn
or cracked belts.
Bi-Annually
1. Check mounting hardware for any loose nuts,
bolts or screws.
2. Check gas connections for leakage.
3. Check for loose electrical connections.
4. Check steam connections for looseness and
leakage.
5. Remove all front panels and vacuum, including
coin drop mechanisms.
6. Check cylinder and front panel seals.
7. Inspect cabinet and inner panels for any damage,
replace or repair as needed.
8. Clean burner tubes and orifice area of any lint
buildup.
Annually
1. Remove burner tubes and clean using water and a
brush.