background image

TORNADO WEBJET 128

Allied Data Technologies

36

Index

A
ASCII Table, 35
asynchronous communication, 3
Asynchronous format, 3
AT command set, 11
AT commands outline, 13
Auto Answer indicator, 5

B
B channels, 1
baud rate, 4
BBS, 2
binary system, 14
bitmapped registers, 14
BRI, Basic Rate Interface, 1
Bulletin Board, 30

C
cable length, 1
Call Clearing Causes, 32
Caller Number Identification, 28
CLI, 28
Command mode, 11
commando mode, 11
configuration program, V
control bit, 3

D
D channel, 1
data mode, 12
Data mode, 12
DB25F connector, 6
DB9F connector, 6
Dial-in configuration, 25

E
E2PROM, 24
escape sequence, 12
Extended AT, 11

F
Firmware uploads, 28
Flash EPROM, 24

G
General settings, 15

I
indicators, 5
installation procedure, V

Internet, 3
Internet Configuration, 3
ISDN, 1
ISDN2, 1
ISP, 2

L
Led, 5

M
Manual
Installation, V
MSN numbers, 26

P
Password, 28
POP, 2
PPP, 2
profiles, 24
protocol priorities, 27
Protocols, 7, 29
provider, 26
PSTN, 1

R
remote access, 3
Remote Configuration, 27
RJ11 connector, 6
RJ45 connector, 7

S
S registers, 11
self-test, 7
Serial port, 7
Specifications, 29
Standard AT, 11
start bit, 3
stop bits, 3
Subaddresses, 25
Suggested further reading, 37

T
TCP/IP address, 3
terminal mode, 9

V
V.110, 2
V.120, 2

W
Website, 30

Summary of Contents for Tornado WebJet 128

Page 1: ...1 Tornado WebJet 128 External ISDN Terminal Adapter Users Manual ...

Page 2: ...TECHNOLOGIES has been informed that such damage could arise Of course this does not detract from out legal liability for intentionally inflicted damage or damage on the basis of gross negligence In relation to the information mentioned in this manual ALLIED DATA TECHNOLOGIES does not warrant that there are no industrial rights of ownership trademarks patents etc This also applies to commonly used ...

Page 3: ...3 4 General settings 15 3 5 Dialing and Answering 16 3 5 1 Dialing an ISDN number 16 3 6 Serial port settings 17 3 6 1 Result codes 20 3 6 2 Other messages 21 3 7 Profiles and identification 22 3 8 Other commands 22 4 Sundries 24 4 1 Settings profiles 24 4 2 Nonvolatile memory settings 24 5 Special applications 25 5 1 Dial in configuration 25 5 1 1 Subaddresses 25 5 1 2 MSN numbers 26 5 1 3 Settin...

Page 4: ... the configuration program Who should read this manual Both starting and experienced users can find the information they need in this manual First of all chapter 1 should prove interesting to the former It covers general information on data communication and the use of the Terminal Adapter The alphabetical description of the commands and the S registers Chapter AT command set and S registers can b...

Page 5: ... responds to an incoming call if the call is actually destined for it For instance if a call is made by a terminal adapter only a terminal adapter will respond the fax and telephone will not This is possible because information is sent along about the kind of telecommunication service This means a beeping fax on the line is a thing of the past With an ISDN2 or BRI Basic Rate Interface connection y...

Page 6: ...ilities of the Internet Service Provider ISP or Point Of Presence POP see Figure 2 Figure 2 Access to an On line Service Internet Configuration You can only gain ISDN access to the Internet if you have a contract with an Internet Service Provider ISP who works with ISDN access You will need the following information from your ISP to configure the Tornado WebJet 128 ISDN access number to be entered...

Page 7: ...data bits 1 stop bit Figure 3 Asynchronous Format Apart from the frame character the speed baud rate has to be set Speed is expressed in terms of Bits per Second bps or baud Possible port speeds are 300 1200 2400 4800 9600 19200 38400 57600 and 115200 bps If data bits control bits and speed are set at the computer end the Tornado WebJet 128 will adapt automatically as soon as an AT command is sent...

Page 8: ...Jet 128 terminal adapter The top of the terminal adapter shows four LEDS Three of them reflect the status of the ISDN connection and the serial port The fourth one indicates whether there is power on the Tornado WebJet 128 Figure 4 Tornado WebJet 128 Top Meaning of the LEDs from left to right DATA B1 B2 PWR Serial data transfer Channel B1 Channel B2 Line power DTR status The Data LED also reflects...

Page 9: ...abase you wish to contact 5 a serial cable and ISDN cable 6 an electrical outlet Connecting the Terminal Adapter 1 Connect the serial ports of the terminal adapter and the computer 2 Take the ISDN cable and click the RJ45 connector into the terminal adapter S0 connection 3 Plug the Tornado WebJet 128 Power adapter into the electrical outlet 4 Plug the Power adapter connector into the power connect...

Page 10: ...n transp B data 57 6 57 6 V 14 9 asyn transp B data 19 2 38 4 V 110 asyn 10 asyn transp B data 115 2 230 4 V 120 asyn 13 asyn transp 2B data 230 4 230 4 V 120 asyn MLP 16 GCI speech B1 B2 voice 230 4 18 GCI data B1 B2 data 230 4 any 27 asyn transp B1 B2 data 115 2 230 4 ML PPP RFC1990 asyn sync 28 asyn transp B1 B2 data 115 2 230 4 TRANSPARENT asyn sync Remote control OK The above list is an examp...

Page 11: ...erminal adapter is connected 3 Select communication speed baud rate the number of data bits and parity For example 115200 bps 8 bits no parity 4 Make sure the program is in terminal mode so that keyed in characters are sent to the terminal adapter The terminal adapter in its turn will echo the characters to screen 5 Then type AT Enter The screen will show AT 6 If the characters appear on screen tw...

Page 12: ...d to the ISDN net BUSY The number you have dialed is busy NO CARRIER The number you have called doesn t support the selected protocol Another explanation is that there is no terminal adapter present at the number you 9 Break the connection There are three ways to do this a Order the BBS to break the connection b Use the command provided by your communication program c Order the modem to break the ...

Page 13: ...rofiles and identification Other commands 3 1 1 Command mode and data mode The terminal adapter has two modes 1 Command mode In this mode the terminal adapter executes commands that are keyed in at the terminal The terminal adapter is in command mode when it isn t on line or in a data connection when it is set to command mode by way of the escape sequence 2 Data mode The terminal adapter is transp...

Page 14: ...te and parity from the initial letters AT in the command line The Terminal Adapter gears itself to it Automatically recognized speeds are 300 1200 2400 4800 9600 19200 38400 57600 and 115200 bps The recognized data formats are 7 bits or 8 bits characters with even odd or no parity bit and 1 stop bit ...

Page 15: ...tandard settings at startup 22 S Show settings 22 Error No index entries found CH Default DTE channel 22 PASSRC Set Remote Control Password 28 REMNBRC Set Remote Control number 27 RM Ring mode 23 V Show list of available protocol names 22 Z Software reset using stored settings 22 3 2 S Registers A number of terminal adapter settings have to be done by means of S registers A number of registers hav...

Page 16: ...ackspace character bs 17 S006 No function in ISDN 16 S007 Connection delay 16 S008 No function in ISDN 16 S025 DTR hysteresis 17 S039 Flow control 17 S095 Protocol and connection messages 17 S110 Active protocol 15 S111 protocol service 15 S112 Detailed call messages 17 S114 Serial asynchronous speed and asynchronous clock selection 18 S117 Timer number of RING messages 18 S121 Action following F ...

Page 17: ...x service 5 V 14 7 PAD service 8 V 120 service 10 Synchronous relay service O Switch to Data mode M 0 2 cnf Communication mode M0 Asynchronous M1 Synchronous M2 Synchronous select DTR O 1 255 10 Select active protocol O7 PPP 1 x B O8 V 14 1 x B O9 V 110 1 x B O10 V 120 1 x B O13 Multi Link V 120 2 x B O16 GCI speech 2 x B O18 GCI data 2 x B O27 Multi Link PPP 2 x B Q 0 6 cnf Communication mode Q0 ...

Page 18: ...TORNADO WEBJET 128 Allied Data Technologies 18 Also refer to D DTR behavior X show result of code selection and data detection W return messages S95 return messages S112 detailed indications ...

Page 19: ... 8 DTR hysteresis in 1 100 seconds S25 0 255 0 Hystérésis DTR en 1 100 secondes ou en secondes si synchrone S39 0 4 3 Flow control 0 No flow control 3 RTS CTS flow control hardware 4 XON XOFF flow control software S95 0 255 0 Protocol and connection messages 1 gives serial port speed not line speed in CARRIER message 2 add ARQ in an error correcting connection 4 CARRIER message on 8 PROTOCOL messa...

Page 20: ... S95 0 W1 CONNECT with serial port speed Also CARRIER and PROTOCOL messages when S95 0 W2 CONNECT with line speed No extended protocol messages when S95 0 X 0 4 4 Dial and busy tone message and detection selection X0 Busy tone and dial tone detection off only CONNECT message X1 Busy tone detection off dial tone detection off CONNECT xxx message X2 Busy tone detection off dial tone detection on CON...

Page 21: ...e Q0 Q5 S0 DSR is always on S1 S2 DSR is on when on line off in rest Numeric Text Meaning Type 0 OK Command executed 1 CONNECT Connection established 1 CONNECT ARQ Error correcting connection 2 RING Incoming call 3 NO CARRIER Connection broken 4 ERROR Error message 5 CONNECT 1200 Connected at 1200 bps 5 CONNECT 1200 ARQ Ditto including error correction 6 NO DIALTONE ISDN network does not respond 7...

Page 22: ...9600 Line speed 9600 bps 54 CARRIER 19200 Line speed 19200 bps 56 CARRIER 38400 Line speed 38400 bps 57 CARRIER 56000 Line speed 56000 bps 58 CARRIER 57600 Line speed 57600 bps 59 CARRIER 64000 Line speed 64000 bps 60 CARRIER 115200 Line speed 115200 bps 66 COMPRESSION CLASS 5 MNP 5 data compression 67 COMPRESSION V42BIS V 42bis data compression 69 COMPRESSION NONE No data compression 70 PROTOCOL ...

Page 23: ...ecksum test I3 Product name and software revision I4 Manufacturer I5 Outline of possible protocols I8 Euro ISDN software version V Show settings S Show settings Z Software reset using stored settings Caution This command completely resets the Tornado WebJet 128 all possible connections will be broken See also S122 F Software reset using factory settings See also S121 W Store current settings Store...

Page 24: ... is fixed in the terminal adapter memory Flash EPROM These settings are loaded into the active profile with the AT F command 4 2 Nonvolatile memory settings The Terminal Adapter settings are stored in a nonvolatile memory E2PROM The commands used are Save register content with AT W Save automatic dial up number 40 characters maximum with AT Z MSN number function with AT NBV120 number always close ...

Page 25: ...ly the Tornado WebJet 128 can dial a number and add extra characters to the telephone number This is limited to ISDN equipment The subaddress service is not a standard feature and needs to be applied for The table given below gives the AT commands for the various types needed to change the default link between protocol and subaddress The link is switched off by not entering a value empty string Ex...

Page 26: ...an be linked to subaddresses and MSN numbers It is possible to link different protocols to one and the same subaddress or MSN number The terminal adapter will select the protocol with the highest priority The following commands can be used to set the protocol priorities Value 0 denotes the highest priority value 254 denotes the lowest priority Priority 255 means the protocol in question doesn t re...

Page 27: ...mmed telephone number Password Check This access code is sent through UUI User to User Information and compared to a set code The code is programmed as follows AT passrc password Z ENTER CLI example In this example your own telephone number is 010 1234567 and the number of the person allowed to do Remote Configuration is 020 7654321 Command s AT RM 0 Ring mode off AT IPRC 254 Set priority AT NBRC ...

Page 28: ... interface according to CCITT I 430 1TR3 S0 connection RJ45 socket Permanent memory for settings Settings may differ per protocol Auto baud detection from 300 to 115200 bps Full interspeeder with XON XOFF and or RTS CTS flow control Self test after power up Data format Data 7 or 8 bits Parity odd even space mark or none Stop bits 1 or 2 Connections Serial port DB9F V 24 RS232 connector Supply by P...

Page 29: ...es questions and other information Allied Data also provides an overview of special offers on communication programs utilities etc Recent drivers for various software packages can also be found at Allied Data The Allied Data BBS can be accessed 24 hours a day at 31 0 181 698 399 Line settings 8 data bits no parity and 1 stop bit with ASCII or ANSI screen emulation This number is accessible both th...

Page 30: ...ector CCITT DBF9F Richting Naam Verkort Pin 109 1 OUT Data carrier detect CD 104 2 OUT Received Data RxD 103 3 IN Transmitted Data TxD 108 4 IN Data terminal ready DTR 5 Signal Ground GND 107 6 OUT Data set ready DSR 105 7 IN Request to send RTS 106 8 OUT Clear to send CTS 125 9 OUT Ring Indicator RI ...

Page 31: ...38 network out of order 29 41 temporary failure 2A 42 switching equipment congestion 2B 43 access information discarded 2C 44 requested circuit channel not available 2F 47 resources unavailable unspecified 31 49 quality of service unavailable 32 50 requested facility not subscribed 39 57 bearer capability not authorised 3A 58 bearer capability not presently available 3F 63 service or option not av...

Page 32: ...el B1 has been selected CLEARED 6 10 Call 6 has been broken off by normal cause 10 AT D 69855044 5 Hello While the first connection is being established a second command follows to dial ISDN number 69855044 subaddress 5 and User Information Hello Note that it isn t necessary to give the O6 command as this protocol is already active OK 6 0 6 Direct response that call number 6 on ISDN access number ...

Page 33: ...ice Control 3 SYN Sync ETX End of Text DC4 Device Control 4 LF Linefeed EOT End of Transm CAN Cancel FF Formfeed ACK Acknowledge EM End of Medium ENQ Enquiry BEL Bell or Alarm SUB Substitute ESC Escape BS Backspace FS File Separator DLE Data Link HT Horizontal Tab GS Group Separator ESC Escape VT Vertical Tab RS Record Separator S P Space CR Carriage Return US Unit Separator DEL Delete NAK Negativ...

Page 34: ... e 101 65 P DLE 16 10 59 3B f 102 66 Q DC1 17 11 60 3C g 103 67 R DC2 18 12 61 3D h 104 68 S DC3 19 13 62 3E i 105 69 T DC4 20 14 63 3F j 106 6A U NAK 21 15 64 40 k 107 6B V SYN 22 16 A 65 41 l 108 6C W ETB 23 17 B 66 42 m 109 6D X CAN 24 18 C 67 43 n 110 6E Y EM 25 19 D 68 44 o 111 6F Z SUB 26 1A E 69 45 p 112 70 ESC 27 1B F 70 46 q 113 71 FS 28 1C G 71 47 r 114 72 GS 29 1D H 72 48 s 115 73 RS 30...

Page 35: ...8 Standards protocols services MCGraw Hill Euro ISDN by J J C Salemans PTT Telecom BV Necessary and valuable information on the PTT Telecom Euro ISDN user network interface PTT Telecom Werken met ISDN by Mike Sapien Greg Piedno ISBN 9051609213 Background information to apply ISDN in actual practice Sybex Het nieuwe handboek PC communication by Henk van Ess ISBN 90 5160 723 7 A crystal clear clarif...

Page 36: ...12 DB25F connector 6 DB9F connector 6 Dial in configuration 25 E E2PROM 24 escape sequence 12 Extended AT 11 F Firmware uploads 28 Flash EPROM 24 G General settings 15 I indicators 5 installation procedure V Internet 3 Internet Configuration 3 ISDN 1 ISDN2 1 ISP 2 L Led 5 M Manual Installation V MSN numbers 26 P Password 28 POP 2 PPP 2 profiles 24 protocol priorities 27 Protocols 7 29 provider 26 ...

Page 37: ...ny Am Josefhaus 17 D 41470 NEUSS Deutschland Tel 49 0 2137 959938 Fax 49 0 2137 76977 Allied Data Technologies Taiwan 8F No 410 Chung Hsiao E Road Sec 5 Taipei Taiwan Tel 886 0 2 8789 1318 Fax 886 0 2 8789 1316 Head office Allied Data Technologies bv Pascalweg 1 Spijkenisse P O box 788 3200 AS Spijkenisse the Netherlands Tel 31 0 181 611 5 22 Fax 31 0 181 614 8 40 E mail info allieddata nl Website...

Reviews: