Repairs
4 - 6
3.
Mark one side of the motor for proper assembly, paying
careful attention that the cartridge will not be installed
upside down. Secure the motor prior to loosening the
5/8-11 bolts.
4.
Remove front housing.
NOTE: Two 5/16” ball checks
and one main body O-ring may be dislodged and
fall free.
5.
With the seal plate removed, press shaft and ball
bearing out of front housing.
Motor Disassembly
NOTE: Disassembling the motor while it’s still under
its warranty period immediately invalidates the war-
ranty. If the motor malfunctions before its warranty
period expires, please contact Allied Systems Com-
pany fi rst before attempting to repair it.
1.
Remove snap ring.
Use caution when removing snap ring. If re-
leased accidentally, it can become an airborne
hazard.
2.
Pry out shaft seal plate with two screwdrivers. Remove
seal plate O-ring from groove in bearing bore.
- Motor Disassembly