Logging Commands
©2008 Allied Telesis Inc. All rights reserved.
Software Version 5.2.1
AlliedWare Plus
TM
Operating System Software Reference C613-50003-00 REV E
10.9
log buffered
Configures the device to store log messages in RAM. Messages stored in RAM are not retained
on the device over a restart. Once the buffered log reaches its configured maximum allowable
size old messages will be deleted to make way for new ones. The buffered log is configured by
default.
Syntax
log buffered
no log buffered
Mode
Configure mode
Examples
To configured the device to store log messages in RAM use the command:
To configure the device to not store log messages in a RAM buffer use the command:
Validation
Commands
show log config
Related Commands
default log buffered
log buffered (filter)
log buffered size
Parameter
Description
no
Configures the device to not store log messages in a RAM buffer
log
Logging control
buffered
Store log messages in a RAM buffer
awplus(config)#
log buffered
awplus(config)#
no log buffered