AT-SBx908 GEN2 Installation Guide for Virtual Chassis Stacking
35
Specifying Ports in the Command Line Interface
The individual ports on the switches in a stack are specified in the
command line interface with the PORT parameter. The format of the
parameter is shown in Figure 8.
Figure 8. PORT Parameter in the Command Line Interface
The three parts of the PORT parameter are described in Table 8.
Here is an example of the PORT parameter on a switch in a stack. It uses
the INTERFACE command to enter the Port Interface mode for ports 15
and 17 on the line card in slot 2 in a switch with the ID number 3:
awplus> enable
awplus# configure terminal
awplus(config)# interface port3.2.15,port3.2.17
Table 8. PORT Parameter Format
Number
Description
Stack ID Number
Designates the switch’s ID number. The
number, which can be from 1 to 4,
identifies the switch in a VCStack. A switch
displays its ID number on the Switch ID
LED on its management panel.
If the Switch ID LED is displaying 0 (zero),
VCStack is disabled and the switch is
functioning as a stand-alone device. The
ID number for a stand-alone switch is 1.
Slot Number
Designates the slot number with the line
card whose ports you want to configure.
For the AT-SBx908 GEN2 Switch this
value can be 1 to 8.
Port Number
Designates a port number on an AT-
SBx908 GEN2 Ethernet line card.
port1
.n.n
Slot Number
Port Number
Stack ID Number
Summary of Contents for AT-FAN08
Page 10: ...Figures 10...
Page 12: ...Tables 12...
Page 16: ...Preface 16...
Page 38: ...Chapter 1 Overview 38...
Page 60: ...Chapter 2 Virtual Chassis Stacking 60...
Page 82: ...Chapter 4 Installing the Chassis 82 Figure 34 Example of Adjusting the Equipment Rack Brackets...
Page 104: ...Chapter 4 Installing the Chassis 104...
Page 140: ...Chapter 5 Powering On the Chassis 140...
Page 166: ...Chapter 7 Cabling the AT XEM2 Line Card Ports 166...