background image

613-000267 Rev. D

Layer 2 Fast 
Ethernet Switch

AT-FS708POE

Installation Guide

Summary of Contents for AT-FS708/POE

Page 1: ...613 000267 Rev D Layer 2 Fast Ethernet Switch AT FS708POE Installation Guide...

Page 2: ...ntioned herein are trademarks or registered trademarks of their respective owners Allied Telesis Inc reserves the right to make changes in specifications and other information contained in this docume...

Page 3: ...ely to cause harmful interference in which case the user will be required to correct the interference at his own expense Note Modifications or changes not expressly approved of by the manufacturer or...

Page 4: ...The indicates that a translation of the safety statement is available in a PDF document titled Translated Safety Statements posted on the Allied Telesis website at www alliedtelesis com and on the do...

Page 5: ...nd Flow Control 24 Network Topologies 26 Power Workgroup Topology 26 PoE Network Topology 27 Chapter 2 Installation 29 Reviewing Safety Precautions 30 Selecting a Site for the Switch 32 Planning the I...

Page 6: ...6 Power Cord Specifications 50 Safety and Electromagnetic Emissions Certifications 51 RJ 45 Twisted Pair Port Connectors and Pinouts 52...

Page 7: ...ng 36 Figure 7 Mounting The Switch on the Wall 37 Figure 8 Attaching the Mounting Brackets 38 Figure 9 Mounting the Switch on the Rack 39 Figure 10 Inserting the SFP 42 Figure 11 Connecting the Twiste...

Page 8: ...Figures 8...

Page 9: ...e 3 Twisted Pair Port LEDs 19 Table 4 SFP Port LED 19 Table 5 IEEE 802 3af Class vs Power Levels 22 Table 6 Twisted Pair Cabling and Distances 33 Table 7 MDI Pin Signals 10Base T or 100Base TX 52 Tabl...

Page 10: ...Tables 10...

Page 11: ...e installation instructions for your AT FS708POE Fast Ethernet switch This preface contains the following sections Safety Symbols Used in this Document on page 12 Where to Find Web based Guides on pag...

Page 12: ...s the safety symbols defined in Table 1 Table 1 Safety Symbols Symbol Meaning Description Caution Performing or omitting a specific action may result in equipment damage or loss of data Warning Perfor...

Page 13: ...o Find Web based Guides The installation and user guides for all Allied Telesis products are available in portable document format PDF on our web site at www alliedtelesis com You can view the documen...

Page 14: ...b Returning Products Products for return or repair must first be assigned a Return Materials Authorization RMA number A product sent to Allied Telesis without a RMA number will be returned to the send...

Page 15: ...chapter contains the follows sections Features on page 16 Port Descriptions on page 17 LEDs on page 19 Power Supply on page 20 Power over Ethernet on page 21 Ethernet Switching Basics on page 23 Netw...

Page 16: ...op mounted to a wall or mounted in a rack The switch is easy to install and does not require software configuration or management Figure 1 illustrates the front and back panels of the AT FS708 POE swi...

Page 17: ...half or full duplex mode The twisted pair ports are IEEE 802 3u compliant and will Auto Negotiate the duplex mode setting Note In order for the switch to set the duplex mode for each port correctly t...

Page 18: ...r network build a high speed backbone network between switches or connect additional end nodes to the network such as high speed servers Figure 2 shows an example of an SFP transceiver Figure 2 SFP Tr...

Page 19: ...cription L A Green A valid link is established on the port Blinking Green Frames are being transmitted received on the port at 10 or 100 Mbps Off No link is established on the port PoE Green A PoE pow...

Page 20: ...internal power supply with a single AC power supply socket on the back panel which features autoswitch AC inputs To power the switch on or off connect or disconnect the power cord provided with the s...

Page 21: ...he powered devices connected to it This can increase the reliability of your network by minimizing the impact to network operations from a power failure PoE can also simplify the installation of your...

Page 22: ...r cabling Alternative A uses the same strands that carry the network traffic Alternative B uses the spare strands The PoE implementation on the AT FS708 POE Fast Ethernet switch is Alternative A where...

Page 23: ...port number where each address was learned When the switch receives a packet it also examines the destination address and by referring to its MAC address table determines the port on which the destin...

Page 24: ...ture to half duplex Note Because the ports on the AT FS708 POE Fast Ethernet switch operate in Auto Negotiate mode only the end nodes connected to the switch must also be configured to operate in the...

Page 25: ...two end nodes attempt to transmit data using the same data link at the same time A collision causes end nodes to stop sending data When the switch needs to stop a 100 Mbps half duplex end node from t...

Page 26: ...ferred to as a power workgroup topology Each workstation or end node is connected directly to a port on the switch Each end node has a dedicated data link to the switch for best performance and reliab...

Page 27: ...ology AT FS708 POE 8 port 10 100TX Unmanaged POE Switch w 1 SFP port POWER 1 2 3 4 5 6 7 8 PoE SFP UPLINK PORT PD ON PD ERR LINK ACT CLASS 1 LASER PRODUCT 1000Base X Access Point Access Point IP Camer...

Page 28: ...Chapter 1 Overview 28...

Page 29: ...page 32 Planning the Installation on page 33 Unpacking the Switch on page 34 Installing the Switch on a Table or Desktop on page 35 Mounting the Switch on a Wall on page 36 Installing the Switch in a...

Page 30: ...only be opened by a trained and qualified technician To avoid the possibility of electric shock disconnect electric power to the product before connecting or disconnecting the LAN cables E1 Warning Do...

Page 31: ...ous condition is not created due to uneven mechanical loading E25 If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than the...

Page 32: ...nd secure The power outlet for the switch should be located near the unit and should be easily accessible The site should provide for easy access to the ports on the front of the switch This will make...

Page 33: ...MDI or MDI X when connected to an end node Therefore you can use either a straight through or crossover twisted pair cable when connecting any network device to a twisted pair port on the switch Tabl...

Page 34: ...shipping material if you need to return the unit to Allied Telesis 2 Place the switch on a level secure surface 3 Ensure the following hardware components are included in your switch package If any i...

Page 35: ...use as much of the original shipping material as possible 2 Attach the four self adhesive rubber feet to the bottom of the switch as shown in Figure 5 Figure 5 Attaching the Rubber Feet 3 Place the sw...

Page 36: ...and attach a mounting bracket provided to each side of the switch using the bracket mounting screws provided as shown Figure 6 Figure 6 Attaching Brackets for Wall Mounting Caution The attached mount...

Page 37: ...ach ethernet cables and power cable 7 To prevent accidental disconnection of the AC power cord fasten the power cord to the wall with the appropriate cable fastener hardware not provided within six in...

Page 38: ...vided as shown Figure 8 Figure 8 Attaching the Mounting Brackets 3 Mount the switch on a 19 inch rack using the screws not provided as shown in Figure 9 775 AT FS708 POE 8 port 10 100TX Unmanaged POE...

Page 39: ...a properly wired earth ground socket outlet An improperly wired socket outlet could place hazardous voltages on accessible metal parts E4 Pluggable Equipment The socket outlet shall be installed near...

Page 40: ...given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient temperature Tmra E35 Caution Installation of the equipment in a rack should be such that t...

Page 41: ...iver from its shipping container and store the packaging material in a safe location Note You must use the original shipping material if you need to return the module to Allied Telesis Warning An SFP...

Page 42: ...When a fiber optic cable is not installed or when you store the SFP always keep the plug in the slot When you do remove the plug keep it for future use Note Unnecessary removal and insertion of an SFP...

Page 43: ...ring on the Switch on page 45 When connecting a twisted pair cable to a port observe the following guidelines An RJ 45 connector should fit snugly into the port on the switch The tab on the connector...

Page 44: ...P transceiver verify that the optical power input to the transceiver is within its dynamic range 1 Remove the dust cover from the SFP transceiver as shown in Figure 12 Figure 12 Removing the Dust Cove...

Page 45: ...onnector on the back panel of the switch as shown in Figure 14 Warning Power cord is used as a disconnection device To de energize equipment disconnect the power cord E3 Figure 14 Connecting the AC Po...

Page 46: ...Chapter 2 Installation 46...

Page 47: ...securely connected to the power source and to the AC connector on the back panel of the switch Verify that the power outlet has power by connecting another device to it Try connecting the unit to ano...

Page 48: ...Chapter 3 Troubleshooting 48 Verify that you are using the appropriate category of twisted pair cable Category 3 or better for 10 Mbps operation and Category 5 and Category 5E for 100 Mbps operation...

Page 49: ...emperature 25 C to 70 C 13 F to 158 F Operating Humidity 5 to 90 non condensing Storage Humidity 5 to 95 non condensing Operating Altitude Range Up to 10 000 feet 3 048 meters Power Specifications AC...

Page 50: ...Appendix A Technical Specifications 50 Power Cord Specifications Cable Type H05VV F 3G 0 75mm2 Maximum Current 6 Amps Voltage Rating AC 250 VAC minimum...

Page 51: ...stallation Guide 51 Safety and Electromagnetic Emissions Certifications EMI FCC Class A CISPR 22 Class A EN55022 Class A C TICK CE Immunity EN55024 Electrical Safety UL 60950 CULUS EN60950 TUV or VDE...

Page 52: ...n RJ 45 connector and port Figure 15 RJ 45 Connector and Port Pin Layout Table 7 lists the RJ 45 pin signals when a twisted pair port is operating in the MDI configuration Table 8 lists the RJ 45 port...

Reviews: