Chapter 2: Installation
36
Cable Specifications
Table 7 contains the cable specifications for the twisted-pair ports.
Note
The twisted pair ports on the switch feature auto-MDI when
operating at 10 or 100 Mbps. A port is configured as MDI or MDI-X
when it is connected to an end node. Consequently, you can use a
straight-through twisted pair cable when connecting any type of
network device to a port on the switch.
Table 7. Twisted-Pair Cabling and Distances
Speed
Type of Cable
Maximum
Operating
Distance
10 Mbps
Standard TIA/EIA 568-B-compliant
Category 3 or better shielded or
unshielded cabling with 100 ohm
impedance and a frequency of 16
MHz.
100 m (328 ft)
100 Mbps
Standard TIA/EIA 568-A-compliant
Category 5 or TIA/EIA 568-B-
compliant Enhanced Category 5
(Cat 5e) shielded or unshielded
cabling with 100 ohm impedance
and a frequency of 100 MHz.
100 m (328 ft)
Summary of Contents for AT-FS909M