Chapter 2 - Installation
Administration Manual (H.323 Version)
AT-VP504E FXO
20
2.
Enable Messages to Syslog Daemon.
Figure 7: Syslog Daemon
3.
Click the Update button at the bottom of the web browser.
4.
Once the AT-VP504E FXO has restarted (this could take 10
to 20 seconds), turn it off, then turn it on again.
5.
With the Syslog opened, watch the AT-VP504E FXO restart.
Messages are sent to the Syslog daemon and their source is
displayed. This IP address is the one assigned to the
AT-VP504E FXO.
To find the IP address with the DHCP Server of your network:
1.
Open the DHCP Server you are using.
2.
Browse through the list of IP addresses and find the one
associated to the MAC address of the AT-VP504E FXO.
Browsing through the list of IP addresses can take some
time.
Click here to enable messages to the
Syslog daemon
Note:
This procedure will only work for one AT-VP504E FXO at a time.
If you are booting several units, you will have no way to tell which IP
address belongs to which AT-VP504E FXO.