AT-VP504E FXO
79
B
Continent Specific Parameters
The following parameters differ depending on the country you are in.
Note that the On – Off sequence is read as follows:
1.0 – 0.85 means that the sequence is 1.0 second On
and 0.85 second Off. The bold number always refer to the
On sequence
Australia Parame-
ters
The following parameters apply if you have selected Australia as
location.
Austria Parame-
ters
The following parameters apply if you have selected Austria as
location.
Table 31: Australia Parameters
Parameter
Value
On – Off Sequence (s)
Elect. Levels
Dial Tone
425 Hz
CONTINUOUS
-20 dBm
Busy Tone
400 Hz
0.375 – 0.375
-20 dBm
Ringing Tone
450 Hz + 450 Hz
0.4 – 0.2 – 0.4 – 2.0
-19 dBm
Special Information Tone
950 Hz
1400 Hz
1800 Hz
0.33
0.33
0.33 – 1.0
-20 dBm
Ring
65 VRMS, 50 Hz
0.4 – 2.0
Impedance
Z
R
= 220
Ω
+ 820
Ω
// 120 nF
Tbrl-Impedance
Z
N
=220
Ω
+ 820
Ω
// 120 nF
FXO Line Attenuation (Input)
-6 dBr
FXO Line Attenuation (Output)
0 dBr
Table 32: Austria Parameters
Parameter
Value
On – Off Sequence (s)
Elect. Levels
Dial Tone
450 Hz
1.0 – 0.85
-20 dBm
Busy Tone
450 Hz
0.45 – 0.45
-13 dBm
Ringing Tone
450 Hz
1.0 – 4.0
-20 dBm
Special Information Tone
950 Hz
1400 Hz
1800 Hz
0.33
0.33
0.33 – 1.0
-20 dBm
Ring
65 VRMS, 50 Hz
1 – 5
Impedance
Z
R
= 270
Ω
+ 750
Ω
// 150 nF
Tbrl-Impedance
Z
N
= 600
Ω
FXO Line Attenuation (Input)
-10 dBr
Summary of Contents for AT-VP504E FXS
Page 1: ...AT VP504E FXO H 323 Administration Manual PN 990 11592 10 Rev C VoIPTalk...
Page 16: ...Chapter 1 Introducing the AT VP504E FXO Administration Manual H 323 Version AT VP504E FXO 8...
Page 76: ...Chapter 5 Software Upgrade Administration Manual H 323 Version AT VP504E FXO 68...
Page 100: ...Appendix C Gatekeeper Registration Logic Administration Manual H 323 Version AT VP504E FXO 92...
Page 112: ...Index Administration Manual H 323 Version AT VP504E FXO 104...