Appendix B - Continent Specific Parameters
Administration Manual (H.323 Version)
AT-VP504E FXO
80
France Parameters
The following parameters apply if you have selected France as
location.
Germany Parame-
ters
The following parameters apply if you have selected Germany as
location.
FXO Line Attenuation (Output)
+3 dBr
Table 32: Austria Parameters
Parameter
Value
On – Off Sequence (s)
Elect. Levels
Table 33: France Parameters
Parameter
Value
On – Off Sequence (s)
Elect. Levels
Dial Tone
330 Hz
CONTINUOUS
-16.9 dBm
Busy Tone
440 Hz
0.5 – 0.5
-19.9 dBm
Ringing Tone
440 Hz
1.5 – 3.5
-19.9 dBm
Special Information Tone
950 Hz
1400 Hz
1800 Hz
0.33
0.33
0.33 – 1.0
-19.9 dBm
Ring
75 VRMS, 50 Hz
1.5 – 3.5
Impedance
Z
R
= 215
Ω
+ 1000
Ω
// 137 nF
Tbrl-Impedance
Z
N
= 600
Ω
FXO Line Attenuation (Input)
-8.9 dBr
FXO Line Attenuation (Output)
-1.9 dBr
Table 34: Germany 1 Parameters
Parameter
Value
On – Off Sequence (s)
Elect. Levels
Dial Tone
425 Hz
0.2 – 0.3, 0.2 – 0.3, 0.2 – 0.8
-16 dBm
Busy Tone
425 Hz
0.17 – 0.43
-16 dBm
Ringing Tone
425 Hz
1.0 – 4.0, 1.0 – 4.0, 1.0 – 4.0
-16 dBm
Special Information Tone
425 Hz
0.17– 0.43
-16 dBm
Ring
75 VRMS, 25 Hz
1 – 4
Impedance
Z
R
= 220
Ω
+ 820
Ω
// 115 nF
Tbrl-Impedance
Z
N
= 220
Ω
+ 820
Ω
// 115 nF
FXO Line Attenuation (Input)
-10 dBr
FXO Line Attenuation (Output)
+3 dBr
Summary of Contents for AT-VP504E FXS
Page 1: ...AT VP504E FXO H 323 Administration Manual PN 990 11592 10 Rev C VoIPTalk...
Page 16: ...Chapter 1 Introducing the AT VP504E FXO Administration Manual H 323 Version AT VP504E FXO 8...
Page 76: ...Chapter 5 Software Upgrade Administration Manual H 323 Version AT VP504E FXO 68...
Page 100: ...Appendix C Gatekeeper Registration Logic Administration Manual H 323 Version AT VP504E FXO 92...
Page 112: ...Index Administration Manual H 323 Version AT VP504E FXO 104...