x950 Series Installation Guide for VCStack
197
3. Configure the VT-100 terminal or terminal emulation program as
follows:
Baud rate: 9600 bps
Data bits: 8
Parity: None
Stop bits: 1
Flow controller: None
Note
The port settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulator program.
4. Press Enter. You are prompted for a user name and password.
5. Enter the default user name and password. They are “manager” and
“friend” (without the quotes), respectively
Note
User names and passwords are case sensitive.
The local management session starts when the User Exec mode
prompt, shown in Figure 124. is displayed.
Figure 124. User Exec Mode Prompt
Note
The User Exec mode is the first level in the command mode
interface. For complete information on the modes and commands,
refer to the
Software Reference for x950 Series Switches,
AlliedWare Plus Operating System
from
.
6. Do one of the following:
To begin configuring the master switch, go to “Configuring the
Master Switch - Part I” on page 200.
If you have already configured the master switch, go to Chapter 11,
“Configuring Member Switches” on page 209.
awplus>
Summary of Contents for x950 Series
Page 12: ...Figures 12 ...
Page 18: ...Preface 18 ...
Page 50: ...Chapter 1 Overview 50 ...
Page 70: ...Chapter 2 XEM2 Ethernet Line Cards 70 ...
Page 134: ...Chapter 5 Installing Power Supplies and Optional XEM2 Line Card 134 ...
Page 146: ...Chapter 7 Installing the Switch in an Equipment Rack 146 ...
Page 162: ...Chapter 8 Installing the Switch on a Wall 162 ...
Page 224: ...Chapter 12 Powering On and Verifying the Stack 224 ...
Page 256: ...Chapter 14 Replacing Modules 256 ...