Chapter 10: Configuring the Master Switch
202
Step 9 adds the member switches as provisioned switches to the master switch. You need to
add one provisioned switch for each member switch to be in the stack.
9
Add the member switches as provisioned switches to the master switch, with the
SWITCH PROVISION command. Assign them unique IDs in the range of 2 to 4. This
example assumes the stack will have three member switches.
awplus(config)# switch 2 provision x950-28
awplus(config)# switch 3 provision x950-28
awplus(config)# switch 4 provision x950-28
Steps 10 to 15 save your changes and reboot the switch.
10
Return to the Privileged Exec mode.
awplus(config)# exit
11
Enter the WRITE command to save your change. If this is the first management
session, the switch adds the configuration file DEFAULT.CFG to flash memory.
awplus# write
Building configuration ...
[OK]
12
Restart the switch with the REBOOT command.
awplus# reboot
reboot system? (y/n):
awplus#
13
Type “Y” for yes.
14
Wait two minutes for the switch to initialize its management software.
15
Check the ID LED in the management panel on the front panel and do one of the
following:
- If the ID LED is displaying the number 1, VCStack is now enabled on the switch. Go
to “Configuring the Master Switch - Part II” on page 203.
- If the ID LED is displaying “0,” VCStack is still disabled. Repeat this procedure,
being sure to issue the WRITE command to save your change before resetting the
switch.
Table 32. Configuring the Master Switch - Part I (Continued)
Step
Description and Command
Summary of Contents for x950 Series
Page 12: ...Figures 12 ...
Page 18: ...Preface 18 ...
Page 50: ...Chapter 1 Overview 50 ...
Page 70: ...Chapter 2 XEM2 Ethernet Line Cards 70 ...
Page 134: ...Chapter 5 Installing Power Supplies and Optional XEM2 Line Card 134 ...
Page 146: ...Chapter 7 Installing the Switch in an Equipment Rack 146 ...
Page 162: ...Chapter 8 Installing the Switch on a Wall 162 ...
Page 224: ...Chapter 12 Powering On and Verifying the Stack 224 ...
Page 256: ...Chapter 14 Replacing Modules 256 ...