x950 Series Installation Guide for VCStack
203
Configuring the Master Switch - Part II
This section contains Part II for configuring the master switch. In this
procedure you do the following:
Designate the types of transceivers to be used in ports 25, 29, 33,
and 37 for the x950-28XSQ and x950-28XTQm switches or ports
49, 53, 57, 61 for the x950-52XSQ switch on the master and
provisioned member switches.
Designate the trunk ports.
To perform Part II, perform the procedure in Table 33.
Table 33. Configuring the Master Switch- Part II
Step
Description and Command
1
Start a new local management session. Refer to “Starting a Local Management
2
Move to the Privileged Exec mode with the ENABLE command.
awplus> enable
3
Move to the Global Configuration mode with the CONFIGURE TERMINAL command.
awplus# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Steps 4 designates the types of transceivers to be used in ports 25, 29, 33, and 37 for the
x950-28XSQ and x950-28XTQm switches or in ports 49, 53, 57, and 61 for the x950-52XSQ
switch on the master switch. The ports support 40Gbps QSFP+ transceivers, 100Gbps
QSFP28 transceivers, and 40Gbps to 10Gbps breakout cables. The default is 40Gbps QSFP+
transceivers.
4
Designate the types of transceivers to be used in ports 25, 29, 33, and 37 for the
x950-28XSQ and x950-28XTQm switches or in ports 49, 53, 57, and 61 for the
x950-52XSQ switch on the master switch with the PLATFORM PORTMODE
INTERFACE command in the Global Configuration mode. You can skip this step for
ports that will be using 40Gbps QSFP+ transceivers because that is the default
setting. You can also skip this step and configure the ports later if you are not using
100Gbps transceivers for the stack trunk. For more information, refer to “Ports for
40Gbps QSFP+ or 100Gbps QSFP28 Transceiver, or Breakout Cables” on page 29
and “PLATFORM PORTMODE INTERFACE” on page 188.
This example configures ports 33 and 37 for 100Gbps transceivers on the master
switch:
awplus(config)# platform portmode interface port1.0.33-1.0.37 100g
Steps 5 to 7 designate the stack ports on the master switch with the STACKPORT command.
Summary of Contents for x950 Series
Page 12: ...Figures 12 ...
Page 18: ...Preface 18 ...
Page 50: ...Chapter 1 Overview 50 ...
Page 70: ...Chapter 2 XEM2 Ethernet Line Cards 70 ...
Page 134: ...Chapter 5 Installing Power Supplies and Optional XEM2 Line Card 134 ...
Page 146: ...Chapter 7 Installing the Switch in an Equipment Rack 146 ...
Page 162: ...Chapter 8 Installing the Switch on a Wall 162 ...
Page 224: ...Chapter 12 Powering On and Verifying the Stack 224 ...
Page 256: ...Chapter 14 Replacing Modules 256 ...