Chapter 2: XEM2 Ethernet Line Cards
60
LEDs
Each port has a single LED that displays link and activity information.
Refer to Table 20.
Cabling
The minimum cable requirements are:
- 100Mbps - Standard TIA/EIA 568-B-
compliant Category 3 unshielded
cabling.
- 1Gbps - Standard TIA/EIA 568-A-
compliant Category 5 or TIA/EIA 568-B-
compliant Enhanced Category 5 (Cat 5e)
unshielded cabling.
- 10Gbps -Standard TIA/EIA 568-C-
compliant Category 6a unshielded
cabling.
Maximum Distance
100 meters (328 feet)
Connector
8-pin RJ-45
Table 19. Twisted Pair Ports on the XEM2-12XT Line Card (Continued)
Specification
Description
Table 20. Port Link and Activity LEDs on the XEM2-12XT Line Card
State
Description
Solid Green
The port has established a 10GBase link
to a network device.
Flashing Green
The port is transmitting or receiving data
at 10GBase.
Solid Amber
The port has established a 100Mbps or
1GBase link to a network device.
Flashing Amber
The port is transmitting or receiving data
at 100Mbps or 1GBase.
Off
Possible causes of this state are listed
here:
- The port has not established a link with
another network device.
- The LEDs are turned off. To turn on the
LEDs, use the eco-friendly button.
Summary of Contents for x950 Series
Page 12: ...Figures 12 ...
Page 18: ...Preface 18 ...
Page 50: ...Chapter 1 Overview 50 ...
Page 70: ...Chapter 2 XEM2 Ethernet Line Cards 70 ...
Page 134: ...Chapter 5 Installing Power Supplies and Optional XEM2 Line Card 134 ...
Page 146: ...Chapter 7 Installing the Switch in an Equipment Rack 146 ...
Page 162: ...Chapter 8 Installing the Switch on a Wall 162 ...
Page 224: ...Chapter 12 Powering On and Verifying the Stack 224 ...
Page 256: ...Chapter 14 Replacing Modules 256 ...