Compliance, safety, and intended use
40
Alvium CSI-2 Cameras User Guide V2.6.2
FPC connectors
Hirose FH55-22S-0.5SH FPC connectors enable compact camera design.
The small-sized connectors are sensitive to mechanical stress and are specified for
maximum 20 mating and unmating cycles. Especially if you are inexperienced with
this connector, be very cautious. If the FPC connector is broken, the camera must
be replaced. To install and operate cameras safely, read this section carefully.
Instructions in
on page 166 include helpful information to
enable proper installation.
•
Avoid stress to FPC connectors.
•
Allow only the FPC cable to touch conductors.
Handling the actuator
•
Move the actuator only between 0 degrees (locked position) and 105 degrees
(open position).
•
Carefully flip the actuator at the middle with your finger nail, see
MIPI CSI-2 FPC cables
FPC cable position
Short circuits of the FPC cable can damage the camera or connected hardware.
•
Insert the FPC cable into the connector with cable guiding tabs matching the
connector’s side guides. See
Connecting FPC cable and FPC connectors
•
Connect the camera and the embedded board (adapter) only as shown by the
arrow printed on the FPC cable, see
Connecting FPC cable and FPC connectors
Figure 2: Hirose FH55-22S-0.5SH FPC connector
Additional information
For technical data and more instructions on the Hirose FH55-22S-0.5SH connector,
see the manufacturer data sheet at
.
Manufacturing FPC cables or embedded boards
If you want to design your own components to connect Alvium CSI-2 cameras to
embedded boards, contact your Allied Vision Sales representative or visit
www.alliedvision.com/en/about-us/contact-us/technical-support-repair-/-rma
.
Conductors
Actuator
Connector rear
i