Specifications
45
Alvium CSI-2 Cameras User Guide V2.6.2
Applied standards
MIPI CSI-2
The MIPI (Mobile Industry Processor Interface) CSI (Camera Serial Interface) -2
standard describes a class of MIPI CSI-2 cameras for still image photography and
video streaming. Generically, MIPI CSI-2 cameras are operated by Direct Register
Access. Alvium CSI-2 cameras have a MIPI CSI-2 interface. They comply with:
•
MIPI CSI-2 V1.1
•
D-PHY V1.1.
V4L2
The current V4L2 framework is described at
Allied Vision provides V4L2
drivers. You can download Allied Vision V4L2 drivers from
www.alliedvision.com/en/products/software/embedded-software-and-drivers
Shock and vibration
Alvium closed and open housing cameras were tested according to the following
standards:
•
IEC 60068-2-6, sinusoidal vibration testing
•
IEC 60068-2-27, shock testing
•
IEC 60068-2-64, random vibration testing.
Cameras were inspected before and after the tests. All tests were passed
successfully:
Condition
Passed
Mechanics
•
The camera housings showed no deformations.
•
The connections between camera components had not come loose.
•
The sensor position was within the specified tolerances of a new camera.
Camera behavior
Camera functionalities were not affected, no deviations occurred.
Image streaming
Images were streamed without errors.
Table 7: Conditions for passed tests