Specifications
69
Alvium CSI-2 Cameras User Guide V2.6.2
1500 C-501m/c NIR
Storage temperature
-20° C to +85° C ambient temperature
Operating temperature
Hardware
option
Housing
Cooling areas
2
Mainboard
3
Bare board
4
Not applicable
-20° C to +85° C
-20° C to +85° C
Open housing
5
-20° C to +65° C
Relative humidity
0% to 80% (non-condensing)
Digital interface
MIPI CSI-2 D-PHY V1.1; 1, 2, or 4 lanes; maximum 1.051 Gbps per lane
Camera controls
V4L2 controls (Video4Linux Access), Direct Register Access
2
See
3
Output by
Device Temperature
4
Ensure that the sensor is operated in the temperature range specified by the manufacturer. For any
questions, please visit
www.alliedvision.com/en/support
5
Temperature values must be observed for the housing
and
for the cooling areas.
Feature
Specification
Table 25: Alvium 1500 C-501m/c NIR specifications (sheet 2 of 2)