background image

Preparing Cameras without

Sensor Cover Glass

Page 8 of 18

9. Instructions for Prosilica GT cameras  –  TCG

At delivery, sensors of TCG cameras are protected by the cover glass fixed by adhesive tapes. This section 

instructs on removing these tapes and the cover glass, starting to disassemble the camera in order to get 
access to the sensor.

For Prosilica GT 

Extended Format housing

 cameras, start with 

9.1. Disassembling Prosilica GT Extended 

Format housing cameras

 on page 8.

For Prosilica 

GT Large Format housing

 cameras, start with 

9.2. Disassembling Prosilica GT Large Format 

housing cameras

 on page 10.

9.1. Disassembling Prosilica GT Extended Format housing cameras

1. Power off and unplug the camera.
2. With a water resistant ink pen, draw a line (a) across the joint between front assembly and body 

assembly. This will serve as an index to reassemble the camera in correct orientation.

3. Loosen and remove the four M2 x 8 socket head cap screws of the front assembly.

4. Detach the front assembly (b) from the body assembly (c).

NOTICE

Damage to the camera electronics and sensor

• Work in a dust-free environment (class 100 or better) with humidity according 

to ESD requirements.

• Observe notes for 

3.1. Electrostatic discharge (ESD)

 on page 1.

• Follow the instructions thoroughly.

About the following instructions

The instructions consist of multiple steps. We recommend you to read the 

instructions first to get an orientation on camera preparation.

 Figure 8: Removing the four M2 x 8 socket head cap screws of the front assembly 

 Figure 9: Detaching the front assembly

a

b

c

Summary of Contents for Alvium

Page 1: ...ing Wear ESD protective clothing Keep components away from your body and clothing Even if you are wearing a wrist strap your body is grounded but your clothes are not 3 2 Sensor damage Follow the inst...

Page 2: ...ewer shows a camera image of a moving shadow This proves proper camera function 4 Continue with the corresponding instructions 6 Instructions for housed Alvium cameras RCG on page 3 7 Instructions for...

Page 3: ...ver glass has been removed Therefore Alvium RCG cameras are calibrated for proper focus before shipping NOTICE Damage to the camera electronics and sensor Work in a dust free environment class 100 or...

Page 4: ...ing the sensor or the back lens use lenses with a maximum protrusion within camera specifications For details see your camera s user guide About the following instructions The instructions consist of...

Page 5: ...5 Take the screwdriver with the other hand 6 On the left side of the sensor carefully push the tool tip of the screwdriver against the corner of the adhesive tape until it starts to come off Continue...

Page 6: ...ng the spatula against the cover glass take the camera into the other hand 14 Rotate the camera with the sensor facing down 15 Slowly release the spatula from the cover glass until it disengages from...

Page 7: ...glass has been removed Therefore Manta RCG cameras are calibrated for proper focus before shipping NOTICE Damage to the camera electronics and sensor Work in a dust free environment class 100 or bette...

Page 8: ...nd unplug the camera 2 With a water resistant ink pen draw a line a across the joint between front assembly and body assembly This will serve as an index to reassemble the camera in correct orientatio...

Page 9: ...ping screws h in place remove the sensor unit i from the lens mount k Continue with 9 3 Removing the taped cover glass on page 12 Figure 10 Front assembly overview sensor unit and lens mount NOTICE Da...

Page 10: ...to the ribbon cable a The ribbon cable is included only for cameras with certain mount options 4 Disengage the flexible contact bar b 5 Continue to flip open the front assembly to an angle of 180 and...

Page 11: ...a line i across the center top of sensor unit and front assembly 8 Remove the sensor unit h from the lens mount k Continuing the disassembly Keep the camera flipped open as described in step 5 The ill...

Page 12: ...mera includes sensor units of Prosilica GT cameras Required tools Before you can remove the TCG please obtain the required tools shown below Required tools Tools short names Purpose Base magnifier or...

Page 13: ...the screwdriver with the other hand 6 On the left side of the sensor carefully push the tool tip of the screwdriver against the corner of the adhesive tape until it starts to come off Continue lifting...

Page 14: ...ly release the spatula from the cover glass until it drops out of the lens mount 16 Continue with 9 4 Reassembling Prosilica GT Extended Format housing cameras on page 15 for Prosilica GT Extended For...

Page 15: ...um torque of 4 lbf in 0 45 Nm 4 Position front assembly and body assembly so that markers g align 5 Mount the front assembly f to the body assembly h 6 Insert and tighten the four M2 x 8 socket head c...

Page 16: ...rews and spacers d and tighten screws at a maximum torque of 3 5 lbf in 0 4 Nm 4 Flip the front assembly g back to the body assembly h to approximately 45 5 Engage the flexible contact bar f to the ma...

Page 17: ...user guide Figure 31 Inserting the four M2 x 10 socket head cap screws of the front assembly NOTICE Damage to the sensor If you want to use your camera without lens observe 3 Safety notes on page 1 NO...

Page 18: ...avt distributors Support www alliedvision com en support www alliedvision com en about us contact us technical support repair rma Offices Europe Middle East and Africa Headquarters Allied Vision Techn...