Camera Link registers
62
Goldeye Camera Link Register Controls Reference V1.0.0
RegSensorTemperatureControlState
Status of the sensor temperature control, which is indicated by the temperature
status LED.
RegSensorTemperatureSetpointActivate
Activates the currently selected temperature setpoint, which is represented by
SensorTemperatureSetpointSelector
.
Register name
RegSensorTemperatureControlState
Register type
IntReg
Access mode
R
Address
0x000B0160
Length (Bytes)
4
Bits used
31..0
Enumeration values:
Value
Name and description
0
Off
Sensor cooling is off
1
Deviated
Sensor temperature deviates from the setpoint value
2
Stable
Sensor temperature is stable at the setpoint
3
LowerLimit
Cooling regulator is working at its lower limit
4
UpperLimit
Cooling regulator is working at its upper limit
5
Alert
Camera temperature has reached an overheat protection threshold
temperature, the cooling and the sensor are powered off to protect the
camera and let it cool down.
Register name
RegSensorTemperatureSetpointActivate
Register type
IntReg
Access mode
W
Address
0x000B0168
Length (Bytes)
4
Bits used
31..0
Value
1